Zone Valve, 2 Way, NC, 1 In Sweat, Taco, Mfr#: V100C2G2ZA024Q4A2

$219,91

Free shipping will be applied on orders over $50

Motorized Zone Valve, Actuator Control Pressure - Maximum Not Applicable, Actuator Control Pressure - Minimum Not Applicable, Actuator Control Signal On/Off, Actuator Return Action Double Acting, Actuator Type Electric, Actuator Voltage 24V AC, Allowable Pressure - Maximum 300 psi, Application Geothermal, Body Material Brass, Body Pattern Two-Way, Bypass Port Coefficient of Volume (Cv) Not Applicable, Close-Off Pressure 125 psi, Coefficient of Volume (Cv) 8.9

9999 in stock

Must order in multiples of 1
Subtotal:
$219.91
Final shipping and tax calculated in checkout
Brand Name: Taco
Mfr #: V100C2G2ZA024Q4A2
Availability: Ships in 1 days
SKU: Category: ,

Analogues

PropertyValue
ItemMotorized Zone Valve
Body MaterialBrass
Voltage24
For Use WithGeothermal Systems
Electrical Connections2-Pin Screw Connectors for Power and End Switch
Safe Working Water PSI300 psi
IncludesEnd Switch
Depth (In.)2 3/8 in
Height (In.)4 1/4 in
Width (In.)5 5/16 in
Coefficient of Volume8.9
Max. Water Temp. (Deg. F)220 Degrees F
Connection Type/Size (In.)Sweat 1
TypeTwo Way, Normally Closed, Geothermal System
Port Connection TypeSweat
Actuator TypeElectric
Body PatternTwo-Way
Close-Off Pressure125 psi
Valve ActionNormally Closed
Port Connection GenderFemale
Valve TypeBall
Installation OrientationVersatile
Coefficient of Volume (Cv)8.9
Spring ActionNon-Spring Return
Fluid Temperature - Minimum20 Degrees F
Includes ActuatorActuator Included
Overall Width5 5/16 in
Operating Temperature - Maximum220 Degrees F
Overall Length4 1/4 in
Stem MaterialBrass
Bypass Port Coefficient of Volume (Cv)Not Applicable
Actuator Control Pressure - MaximumNot Applicable
Actuator Control SignalOn/Off
ApplicationGeothermal
For MediaSteam, Water, Water-Ethanol Solution to 25%, Water-Glycol Solution to 50%, Water-Methanol Solution to 25%
Overall Depth2 3/8 in
Actuator Control Pressure - MinimumNot Applicable
Actuator Return ActionDouble Acting
Fluid Temperature - Maximum220 Degrees F
Allowable Pressure - Maximum300 psi
Gasket/Plug MaterialEPDM
Actuator Voltage24V AC
Port Connection Size1 in
Country of Origin (subject to change)United States
Package Quantity1
TAGS:
#Zone Valve
#2 Way
#1 In Sweat
#Taco
#Mfr: V100C2G2ZA024Q4A2
#Taco
#mfr:V100C2G2ZA024Q4A2
#part number:V100C2G2ZA024Q4A2
#pn:V100C2G2ZA024Q4A2
#part code:V100C2G2ZA024Q4A2
#item number:V100C2G2ZA024Q4A2
#product code:V100C2G2ZA024Q4A2
#manufacturer number:V100C2G2ZA024Q4A2
#manufacturers part number:V100C2G2ZA024Q4A2
#mfn:V100C2G2ZA024Q4A2

Reviews

There are no reviews yet.

Add a review