Property | Value |
---|---|
Item | UPS System |
UPS Type | Line Interactive |
Power Rating | 650VA |
Mounting | Tower |
Wattage | 360 W |
Input Voltage | 120V AC |
Output Voltage | 110/115/120V |
Backup Time (Half/Full Load) | 5.7 min/0.5 min |
Outlet Type | (2) Surge; (4) UPS/Surge |
Number of Outlets | 6 |
Housing Material | ABS |
NEMA Receptacle Configuration | (6) 5-15R |
NEMA Plug Configuration | 5-15P |
Transfer Time | 6 milliseconds |
Width | 11.8 in |
Storage Temperature Range | +5 to +113 degrees Fahrenheit / -15 to +45 degrees Celsius |
Audible Alarm | Audible alarm indicates low-battery, fault, overload and replace-battery status |
UPS AC Suppression Joule Rating | 316 |
Low Voltage Transfer to Battery Power (Setpoint) | 89 |
Nominal Input Voltage(s) Supported | 120V AC |
Rated input current (Maximum Load) | 6A |
Frequency Compatibility | 60 Hz |
Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 89 to 145 |
Half Load Runtime (min.) | 5.7 min. (180w) |
UPS AC Suppression Response Time | Instantaneous |
Output Watt Capacity (Watts) | 360 |
Communications Interface | None |
Output Voltage Regulation (Line Mode) | 120V (+9%, -12%) |
Output Volt Amp Capacity (VA) | 650 |
Output Voltage Regulation (Battery Mode) | 120V (+/- 10%) |
Primary UPS Depth (mm) | 300 |
Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
Individually Controllable Load Banks | No |
UPS Dataline Suppression | N/A |
High Voltage Transfer to Battery Power (Setpoint) | 145 |
Primary Form Factor | Tower |
Installation Form Factors Supported with Included Accessories | Tower |
Nominal Output Voltage(s) Supported | 110V; 115V; 120V |
Battery Recharge Rate (Included Batteries) | 8 hours (10% to 90%) |
EMI / RFI AC Noise Suppression | Yes |
AC Mode Efficiency Rating (100% Load) | 0.95 |
UPS Input Cord Length (ft.) | 5 |
Undervoltage Correction | Input voltages between 89 and 108 are boosted by 18% |
DC System Voltage (VDC) | 12 |
UPS Power Module Dimensions (hwd, in.) | 5.6 x 4 x 11.8 |
UPS Certification Details | UL1778: 2014 5th EDITION; CAN/CSA-C22.2 NO. 107.3:2014 3rd EDITION; |
Output AC Waveform (Battery Mode) | PWM sine wave |
Relative Humidity | 0 to 90%, non-condensing |
LED Indicators | 3 LEDs indicate online mode (green), battery mode (yellow) and fault mode (red) |
Overvoltage Correction | Input voltages between 132 and 145 are reduced by 15% |
UPS Certifications | Meets FCC Part 15 Category A (EMI); Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA) |
Expandable Runtime | No |
Recommended Electrical Service | 15A 120V |
AC Mode BTU / Hr. (Full Load) | 24 |
Switches | Controls off/on power status |
Input Phase | Single-Phase |
Primary UPS Height (mm) | 142 |
Country of Origin (subject to change) | China |
Package Quantity | 1 |
UPS System, 650VA, 6 Outlets, Tower, Out: 110/115/120V , In:120V AC, Tripp Lite, Mfr#: VS650T
$99,99
Free shipping will be applied on orders over $50
9999 in stock
Subtotal:
$99.99
You must be logged in to post a review.
Reviews
There are no reviews yet.