Property | Value |
---|---|
Item | Phase Monitor Relay |
Item - Relay | Phase Monitor Relay |
Input or Control Voltage | 480 to 600V AC |
AC Contact Rating - Relay | 10A @ 277V |
DC Contact Rating - Relay | 10A @ 30V |
Number of Pins - Relay | 12 |
Mounting - Relay | DIN Rail |
Contact Form - Relay | DPDT |
Pick Up Range | 460 to 600VAC |
Over Voltage | Fixed 110% of Line Voltage Setting |
Drop-Out Range | 80% to 95% |
Under Voltage | 432 to 540V AC |
Phase Loss Sensitivity | Yes |
Phase Loss Time Delay | 0.1 sec |
Phase Reversal | Yes |
Phase Reversal Time Delay | 0.1 sec |
Phase Unbalance | 2 to 10% |
Phase Unbalance Time Delay | 0.3 to 30.0 sec |
Restart | Auto, Manual |
Restart Time Delay | 1 to 300 sec |
Body Height - Relay | 3.5 in |
Phase | 3 |
Contact Amp Rating (Resistive) | 10 |
Base Type | DIN Rail |
Number of Contacts | 2 |
Input or Control Voltage Range | 480 to 600VAC |
Trip Delay | Power Up and Restart After Fault Clear: 1.00 to 300.0 sec., Phase Loss and Reversal: 100 msec., Phase Unbalance: 0.30 to 30.0 sec., Undervoltage: 0.30 to 30.0 sec., Overvoltage: 0.30 to 30.0 sec. |
Input Voltage | 480 to 600V AC |
Body Depth - Relay | 2.2 in |
Overall Height - Relay | 2.4 in |
Body Width - Relay | 2.1 in |
Pins | 0 |
Contact Form | DPDT |
Standards | CE Certified, cULus Listed |
Frequency | 50/60 Hz |
For Use With | Sensors |
Current Rating | 10 A |
Overvoltage | Fixed 110% of Line Voltage Setting |
Body Depth | 2.4 in |
Minimum Operating Temperature | -18.4 Degrees F |
Body Height | 3.5 in |
Mechanical Operating Durability | 10,000,000 |
Undervoltage | 190 to 500V AC |
Maximum Switching Capacity | 40 VA |
Contact Rating (AC) | 10 A @ 277V |
Power Consumption | 40 VA |
Monitored Parameters | Overvoltage, Phase Loss, Phase Reversal, Phase Unbalance, Undervoltage |
Number of Pins | 12 |
Body Width | 2.1 in |
Maximum Switching Voltage | 660V |
Overall Depth | 2.4 in |
Mounting Style | DIN Rail |
Maximum Operating Temperature | 149 Degrees F |
Contact Rating (DC) | 10 A @ 30V |
Electrical Operating Durability | 100,000 |
Protection | Phase Loss, Phase Reversal, Voltage Unbalance, Undervoltage u0026 Overvoltage |
Minimum/Maximum Voltage | 156-550V (PMDU); 77-152V (PMD120): 345-660V (PMD575), all 50/60Hz.+5% |
Life | Mechanical: 10,000,000 operations, Full Load: 100,000 operations |
Temperature | -28°to 65°C (-18°to 149°F) |
Monitored Voltage | 460-600V AC |
Enclosure Style | Mounts on 35mm DIN rail or panel mounted, DIN-Rail |
Output Contacts | 10A @ 277V AC/30V DC; 1/2HP @ 120/240V AC (N.O.),1/3HP @ 120/240V AC (N.C.), B300 Pilot Duty, R300 (N.O.) |
Load (Burden) | Less than 40 VA |
Configuration / Contact Rating | DPDT. 10A @ 277V AC/30V DC; 1/2HP @ 120/240V AC (N.O.), 1/3HP @ 120/240V AC (N.C.) |
Reset | As standard, the PMD Series relays are in the Automatic Reset mode. However, they can be set in the Manual Reset mode by connecting an external N.C. switch across terminals 4 and 5. Upon application of line voltage, the PMD Series will go into Manual Reset mode if it recognizes a closure across terminals 4 and 5. After a fault clears, the relay will not reset until the N.C. switch is opened. |
Output | 10A DPDT |
Country of Origin (subject to change) | United States |
Package Quantity | 1 |
3 Phase Monitor Relay, DPDT, 600VAC, 0 Pin, Macromatic, Mfr#: PMD575
$136,14
Free shipping will be applied on orders over $50
Phase Monitor Relay, Contact Form DPDT, Contact Rating (AC) 10 A @ 277V, Contact Rating (DC) 10 A @ 30V, Current Rating 10 A, Input Voltage 480 to 600V AC, Monitored Parameters Overvoltage, Phase Loss, Phase Reversal, Phase Unbalance, Undervoltage, Number of Pins 12, Restart Auto, Manual, Restart Time Delay 1 to 300 sec, Mounting Style DIN Rail, Body Depth 2.4 in, Body Height 3.5 in, Body Width 2.1 in, Electrical Operating Durability 100,000, For Use With Sensors, Frequency 50/60 Hz