Property | Value |
---|---|
Item | Phase Monitor Relay |
Item - Relay | Phase Monitor Relay |
Input or Control Voltage | 190 to 500V AC |
AC Contact Rating - Relay | 10A @ 277V |
DC Contact Rating - Relay | 7A @ 30V |
Base Type - Plug In Relay | Octal |
Number of Pins - Relay | 8 |
Mounting - Relay | Plug In |
Contact Form - Relay | SPDT |
Over Voltage | Fixed 110% of Line Voltage Setting |
Pick Up Range | 190 to 500VAC |
Drop-Out Range | 75% to 95% |
Under Voltage | 171 to 450V AC |
Phase Loss Sensitivity | Yes |
Phase Loss Time Delay | 0.1 sec |
Phase Reversal | Yes |
Phase Reversal Time Delay | 0.1 sec |
Phase Unbalance | 6% |
Phase Unbalance Time Delay | 4.0 sec |
Restart | Auto, Manual |
Restart Time Delay | 2 sec |
Body Height - Relay | 2.9 in |
Voltage Unbalance | 6 |
Phase | 3 |
Body Depth - Relay | 2.4 in |
Socket | 5X852 |
Contact Form | SPDT |
Base Type | Octal |
Contact Amp Rating (Resistive) | 10 |
Power Rating | 3 |
Body Width - Relay | 1.7 in |
Input Voltage | 190 to 500V AC |
Pins | 8 |
Number of Contacts | 1 |
Trip Delay | Power Up and Restart After Fault Clear: 2 sec., Phase Loss and Reversal: 100 msec., Phase Unbalance: 4 sec., Undervoltage: 4 sec., Overvoltage: 4 sec. |
Input or Control Voltage Range | 190 to 500VAC |
Overall Height - Relay | 3.0 in |
Standards | CE Certified, cURus, UL Listed |
Number of Pins | 8 |
Body Width | 1.7 in |
Maximum Switching Voltage | 550V |
Body Height | 2.4 in |
Contact Rating (DC) | 7 A @ 30V |
Frequency | 50/60 Hz |
Base Shape | Octal |
Mounting Style | Plug-In |
Maximum Switching Capacity | 40 VA |
Mechanical Operating Durability | 10,000,000 |
Contact Rating (AC) | 10 A @ 277V |
For Use With | Sensors |
Body Depth | 2.9 in |
Overall Depth | 2.4 in |
Monitored Parameters | Overvoltage, Phase Loss, Phase Reversal, Phase Unbalance, Undervoltage |
Socket Code | A |
Electrical Operating Durability | 100,000 |
Power Consumption | 40 VA |
Overvoltage | Fixed 110% of Line Voltage Setting |
Maximum Operating Temperature | 149 Degrees F |
Minimum Operating Temperature | -18.4 Degrees F |
Undervoltage | 190 to 500V AC |
Current Rating | 10 A |
Output | 10A SPDT |
Monitored Voltage | 190-500V AC |
Life | Mechanical: 10,000,000 operations, Full Load: 100,000 operations |
Reset | As standard, the PMP Series relays are in the Automatic Reset mode. However, they can be set in the Manual Reset mode by connecting an external N.C. switch across terminals 6 and 7. Upon application of line voltage, the PMP Series will go into Manual Reset mode if it recognizes a closure across terminals 6 and 7. After a fault clears, the relay will not reset until the N.C. switch is opened. |
Configuration / Contact Rating | SPDT. 10A @ 277V AC / 7A @ 30V DC;. nt1HP @ 250V AC, 1/2HP @ 125V AC, C300 Pilot Duty |
Temperature | -28°to 65°C (-18°to 149°F) |
Enclosure Style | Plug-in case utilizing industry-standard 8 pin octal sockets, Plug-in |
Protection | Phase Loss, Phase Reversal, Voltage Unbalance, Undervoltage u0026 Overvoltage |
Output Contacts | 10A @ 277V AC / 7A @ 30V DC; |
Load (Burden) | Less than 40 VA |
Standard Modifications | Fixed Trip Points u0026 Time Delays (w/ Adjustable Monitored Voltage); |
Minimum/Maximum Voltage | 156-550V, 50/60Hz.+5% |
Country of Origin (subject to change) | United States |
Package Quantity | 1 |
3 Phase Monitor Relay, SPDT, 500VAC, 8 Pin, Macromatic, Mfr#: PMPU-FA8
$77,19
Free shipping will be applied on orders over $50
Phase Monitor Relay, Base Shape Octal, Contact Form SPDT, Contact Rating (AC) 10 A @ 277V, Contact Rating (DC) 7 A @ 30V, Current Rating 10 A, Input Voltage 190 to 500V AC, Monitored Parameters Overvoltage, Phase Loss, Phase Reversal, Phase Unbalance, Undervoltage, Number of Pins 8, Restart Auto, Manual, Restart Time Delay 2 sec, Mounting Style Plug-In, Body Depth 2.9 in, Body Height 2.4 in, Body Width 1.7 in, Electrical Operating Durability 100,000, For Use With Sensors, Frequency 50/60 Hz
9999 in stock
Must order in multiples of 1
Subtotal:
$77.19
You must be logged in to post a review.
Reviews
There are no reviews yet.