Property | Value |
---|---|
Item | Phase Ctrl Relay,200-240VAC In 8A,Dpdt |
Response Time | u003c= 300 ms |
Standards | EN/IEC 60255-1 |
Width | 22.5 mm |
Vibration Resistance | 0.075 mm 10-58.1 Hz) not in operation IEC 60068-2-6 || 1 gn 10-58.1 Hz) not in operation IEC 60068-2-6 || 0.035 mm 58.1-150 Hz) in operation IEC 60068-2-6 || 0.5 gn 58.1-150 Hz) in operation IEC 60068-2-6 |
Mounting Support | 35 mm DIN rail conforming to EN/IEC 60715 |
Pollution Degree | 3 IEC 60664-1 || 3 UL 508 |
Mounting Position | any position |
Ambient Air Temperature For Operation | -20-50°C 60 Hz || -20-60°C 50 Hz AC/DC |
Voltage Detection Threshold | u003c 100 V AC |
Maximum Switching Voltage | 250 V AC |
Output Contacts | 2 C/O |
Maximum Switching Current | 8 A AC |
Relative Humidity | 93-97 % 25-55°C IEC 60068-2-30 |
Time Delay Drift | u003c= 0.05 % per degree centigrade depending permissible ambient air temperature || u003c= 1 % within the supply voltage range |
[Us] Rated Supply Voltage | 200...240 V AC |
Power Consumption In Va | 10-10 VA 240 V AC 60 Hz |
Control Circuit Voltage Limits | 20 % + 20 % Un |
Relay Name | RM22TA |
Threshold Adjustment Voltage | 2...20 % of Un selected |
Supply Frequency | 50...60 Hz +/- 10 % |
Ip Degree Of Protection | IP20 IEC 60529 terminals) || IP40 IEC 60529 housing) || IP50 IEC 60529 front panel) |
Relay Monitored Parameters | asymmetry || phase failure detection || phase sequence |
Setting Accuracy Of The Switching Threshold | +/- 10 % of the full scale |
Measurement Range | 200...240 V voltage AC |
Contacts Material | cadmium free |
Connections - Terminals | screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end || screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end || screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end || screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end |
Switching Capacity In Va | 2000 VA |
Relay Type | control relay |
Housing Material | self-extinguishing plastic |
Insulation Resistance | u003e 100 MOhm 500 V DC IEC 60255-27 |
Dielectric Test Voltage | 2.5 kV AC 50 Hz, 1 min IEC 60255-27 |
Mechanical Durability | 10000000 cycles |
Product Or Component Type | 3-phase control relay |
Tightening Torque | 0.6-1 N.m IEC 60947-1 |
Utilisation Category | AC-15 IEC 60947-5-1 || DC-13 IEC 60947-5-1 || AC-1 IEC 60947-4-1 || DC-1 IEC 60947-4-1 |
Shock Resistance | 15 gn 11 ms) not in operation IEC 60068-2-27 || 5 gn 11 ms) in operation IEC 60068-2-27 |
Switching Threshold Drift | u003c= 0.05 % per degree centigrade depending permissible ambient air temperature || u003c= 1 % within the supply voltage range |
Electromagnetic Compatibility | immunity for residential, commercial and light-industrial environments EN/IEC 61000-6-1 || immunity for industrial environments EN/IEC 61000-6-2 || emission standard for residential, commercial and light-industrial environments EN/IEC 61000-6-3 || emission standard for industrial environments EN/IEC 61000-6-4 || electrostatic discharge 6 kV contact discharge)level 3 IEC 61000-4-2 || electrostatic discharge 8 kV air discharge)level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test 10 V/mlevel 3 IEC 61000-4-3 || electrical fast transient/burst immunity test 4 kV direct)level 4 IEC 61000-4-4 || electrical fast transient/burst immunity test 2 kV capacitive coupling)level 4 IEC 61000-4-4 || surge immunity test 4 kV common mode)level 4 IEC 61000-4-5 || surge immunity test 2 kV differential mode)level 4 IEC 61000-4-5 || conducted and radiated emissionsclass B group 1 CISPR 11 || conducted and radiated emissionsclass B CISPR 22 |
Product Certifications | GL || EAC || UL || CSA || RCM || CCC || CE |
Supply Voltage Limits | 160-288 V AC |
Run-Up Delay At Power-Up | 650 ms |
Voltage Range | 200...240 V phase to phase |
Measurement Error | u003c 1 % over the whole range with voltage variation || u003c 0.05 %/°C with temperature variation |
Hysteresis | 2-2 % fixed selectable |
Maximum Measuring Cycle | 150 ms measurement cycle as true rms value |
Immunity To Microbreaks | 10 ms |
Adjustment Of Asymmetry Threshold | 5...15 % of Un selected |
Electrical Durability | 100000 cycles |
Reset Time | 1500 ms at maximum voltage |
Minimum Switching Current | 10 mA 5 V DC |
Setting Accuracy Of Time Delay | 0.916666666666667 |
Time Delay Type | adjustable 0.1...30 s, +/- 10 % of the full scale value on crossing the threshold Tt |
Repeat Accuracy | +/- 0.5 % input and measurement circuit || +/- 3 % time delay |
Overvoltage Category | III IEC 60664-1 || III UL 508 |
Phase | 3 phase |
Status Led | LED (Yellow) relay ON || LED (Green) power ON |
Ambient Air Temperature For Storage | -40-70°C |
Contacts Type And Composition | 2 C/O |
Control Type | with test button |
Range of Product | Harmony Control Relays |
Country of Origin (subject to change) | Indonesia |
Package Quantity | 1 |
3-phase control relay, Harmony Control Relays, 8A, 2CO, 200...240V AC, Schneider Electric, Mfr#: RM22TA31