Property | Value |
---|---|
Item | Overload Module |
Voltage | 24V AC |
Phase | Three |
Thermal Setting Range (A) | 3.00 to 12.00 |
For Use With | LUxB32, LUxS12, LUxS32 Power Bases, Mfr. Series LUxB12 |
Number of Poles | 3 |
Sensing Method | Electronic |
Current Range | 3.00 to 12.0A |
Trip Class | 10 |
Reset Type - Relay | Manual |
Features | Earth Fault Protection |
Trip Class - Overload | 10 |
Standards | ASEFA, ATEX Compliant, CCC, CE, CSA, CSA C22.2, EAC, EN 60947-6-2, Green Premium RoHS/REACH, IEC 60947-6-2, UL Listed |
Coil Voltage | 24V AC |
Terminal Connection Type | Wire Leads |
Maximum Voltage Rating | 690V AC |
Minimum Operating Temperature | -13 Degrees F |
Compatible with Series | TeSys Ultra |
Maximum Operating Temperature | 158 Degrees F |
Minumum Rated Motor Current Adjustment | 3 A |
Maximum Rated Motor Current Adjustment | 12 A |
Reset Type | Manual |
Compatible with Manufacturer Model Number | LU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380 |
Compatible Manufacturer Part Number | LU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380 |
Compatible Manufacturer Model Number | LU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380 |
For Use with Mfr. Model Number | LU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380 |
For Use With Mfr. Model Number | LU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380 |
Immunity To Voltage Dips | 70 % / 500 ms IEC 61000-4-11 |
Product Specific Application | basic protection and advanced functions, communication |
Vibration Resistance | 2 gn 5-300 Hz power poles open IEC 60068-2-6 || 4 gn 5-300 Hz power poles closed IEC 60068-2-6 |
Non-Dissipating Shock Wave | 1 kV serial mode IEC 60947-6-2 || 2 kV common mode IEC 60947-6-2 |
Utilisation Category | AC-44 || AC-43 || AC-41 |
Control Circuit Voltage Limits | 20 to 26.5 V AC 24 V in operation || 14.5 V AC 24 V drop-out |
Resistance To Fast Transients | 2 kV 3 serial link IEC 61000-4-4 || 4 kV 4 all circuits except for serial link IEC 61000-4-4 |
Operating Time | 35 ms opening with LUB12 control circuit || 35 ms opening with LUB32 control circuit || 35 ms opening with LUB38 control circuit || 70 ms closing with LUB12 control circuit || 70 ms closing with LUB32 control circuit || 70 ms closing with LUB38 control circuit |
Product Compatibility | power base LUB12 || power base LUB32 || power base LUB38 || power base LUB120 || power base LUB320 || power base LUB380 || reversing contactor breaker LU2B12B || reversing contactor breaker LU2B32B |
Tripping Threshold | 14.2 x Ir +/- 20 % |
Fixing Mode | plug-in front face) |
Load Type | 3-phase motor self-cooled |
Motor Power Kw | 5.5 kW 400 to 440 V AC 50/60 Hz || 5.5 kW 500 V AC 50/60 Hz || 9 kW 690 V AC 50/60 Hz |
Compatibility Code | LUCB |
Network Frequency | 40 to 60 Hz |
[Ue] Rated Operational Voltage | 690 V AC |
Phase Failure Sensitivity | yes |
Ambient Air Temperature For Storage | -40-85°C |
Safe Separation Of Circuit | 400 V SELV between the control and auxiliary circuits IEC 60947-1 || 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1 |
Thermal Protection Adjustment Range | 3-12 A |
Product Name | TeSys Ultra |
Heat Dissipation | 2-2 W control circuit with LUB12 || 3-3 W control circuit with LUB32 || 3-3 W control circuit with LUB38 |
[Ui] Rated Insulation Voltage | 690 V IEC 60947-6-2 || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1 |
Ambient Air Temperature For Operation | -25-70°C |
Product Or Component Type | advanced control unit |
[Uimp] Rated Impulse Withstand Voltage | 6 kV IEC 60947-6-2 |
Device Application | motor control || motor protection |
Function Available | manual reset || protection against phase failure and phase imbalance || protection against overload and short-circuit || earth fault protection |
Typical Current Consumption | 140 mA 24 V AC I maximum while closing with LUB12 || 220 mA 24 V AC I maximum while closing with LUB32 || 220 mA 24 V AC I maximum while closing with LUB38 || 70 mA 24 V AC I rms sealed with LUB12 || 90 mA 24 V AC I rms sealed with LUB32 || 90 mA 24 V AC I rms sealed with LUB38 |
Immunity To Microbreaks | 3 ms |
[Uc] Control Circuit Voltage | 24 V AC |
Resistance To Radiated Fields | 10 V/m 3 IEC 61000-4-3 |
Height | 66 mm |
Ip Degree Of Protection | IP20 front panel and wired terminals IEC 60947-1 || IP20 other faces IEC 60947-1 || IP40 front panel outside connection zone IEC 60947-1 |
Product Certifications | CE || UL || CSA || CCC || EAC || ASEFA || ATEX || Marine |
Device Short Name | LUCB |
Fire Resistance | 960°C parts supporting live components IEC 60695-2-12 || 650°C IEC 60695-2-12 |
Immunity To Radioelectric Fields | 10 V IEC 61000-4-6 |
Depth | 60 mm |
Reset | manual reset |
Shock Resistance | 10 gn power poles open IEC 60068-2-27 || 15 gn power poles closed IEC 60068-2-27 |
Protective Treatment | TH IEC 60068 |
Thermal Overload Class | class 10 40-60 Hz -25-70°C IEC 60947-6-2 || class 10 40-60 Hz -25-70°C UL 508 |
Range | TeSys |
Operating Altitude | 6561.68 ft (2000 m) |
Resistance To Electrostatic Discharge | 8 kV 3 in open air IEC 61000-4-2 || 8 kV 4 on contact IEC 61000-4-2 |
Width | 45 mm |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
Ovrload Modul, 3 to 12A, Class 10, 3P, 24VAC, Schneider Electric, Mfr#: LUCB12B
$187,99
Free shipping will be applied on orders over $50
Overload Module, Maximum Rated Motor Current Adjustment 12 A, Minumum Rated Motor Current Adjustment 3 A, Coil Voltage 24V AC, Compatible with Series TeSys Ultra, Terminal Connection Type Wire Leads, Trip Class 10, Phase Three, Maximum Voltage Rating 690V AC, Reset Type Manual, Standards ASEFA, ATEX Compliant, CCC, CE, CSA, CSA C22.2, EAC, EN 60947-6-2, Green Premium RoHS/REACH, IEC 60947-6-2, UL Listed, Compatible with Grainger Part Number 5AB63, 5AB64, 5AB65, 5AB67
9999 in stock
Must order in multiples of 1
Subtotal:
$187.99
You must be logged in to post a review.
Reviews
There are no reviews yet.