Property | Value |
---|---|
Item | Overload Module |
Voltage | 24V AC |
Phase | Three |
Thermal Setting Range (A) | 4.50 to 18.00 |
For Use With | LUxS32 Power Bases, Mfr. Series LUxB32 |
Trip Class | 10 |
Features | Earth Fault Protection |
Trip Class - Overload | 10 |
Current Range | 4.50 to 18.0A |
Sensing Method | Electronic |
Number of Poles | 3 |
Reset Type - Relay | Manual |
Standards | ASEFA, ATEX Compliant, CCC, CE, CSA, CSA C22.2, EAC, EN 60947-6-2, Green Premium RoHS/REACH, IEC 60947-6-2, UL Listed |
Maximum Operating Temperature | 158 Degrees F |
Compatible with Series | TeSys Ultra |
Compatible with Manufacturer Model Number | LU2B32B, LUB32, LUB320, LUB38, LUB380 |
Terminal Connection Type | Wire Leads |
Minimum Operating Temperature | -13 Degrees F |
Minumum Rated Motor Current Adjustment | 4.5 A |
Maximum Voltage Rating | 690V AC |
Maximum Rated Motor Current Adjustment | 18 A |
Reset Type | Manual |
Coil Voltage | 24V AC |
Compatible Manufacturer Part Number | LU2B32B, LUB32, LUB320, LUB38, LUB380 |
Compatible Manufacturer Model Number | LU2B32B, LUB32, LUB320, LUB38, LUB380 |
For Use with Mfr. Model Number | LU2B32B, LUB32, LUB320, LUB38, LUB380 |
For Use With Mfr. Model Number | LU2B32B, LUB32, LUB320, LUB38, LUB380 |
Product Specific Application | basic protection and advanced functions, communication |
Resistance To Radiated Fields | 10 V/m 3 IEC 61000-4-3 |
Product Name | TeSys Ultra |
Compatibility Code | LUCB |
Operating Time | 35 ms opening with LUB32 control circuit || 35 ms opening with LUB38 control circuit || 70 ms closing with LUB32 control circuit || 70 ms closing with LUB38 control circuit |
Resistance To Fast Transients | 2 kV 3 serial link IEC 61000-4-4 || 4 kV 4 all circuits except for serial link IEC 61000-4-4 |
Product Compatibility | power base LUB32 || power base LUB38 || power base LUB320 || power base LUB380 || reversing contactor breaker LU2B32B |
Device Short Name | LUCB |
Fixing Mode | plug-in front face) |
Product Certifications | CE || UL || CSA || CCC || EAC || ASEFA || ATEX || Marine |
Immunity To Voltage Dips | 70 % / 500 ms IEC 61000-4-11 |
Immunity To Radioelectric Fields | 10 V IEC 61000-4-6 |
[Ue] Rated Operational Voltage | 690 V AC |
Depth | 60 mm |
Heat Dissipation | 3-3 W control circuit with LUB32 || 3-3 W control circuit with LUB38 |
[Ui] Rated Insulation Voltage | 690 V IEC 60947-6-2 || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1 |
Height | 66 mm |
Ambient Air Temperature For Operation | -25-70°C |
Typical Current Consumption | 220 mA 24 V AC I maximum while closing with LUB32 || 220 mA 24 V AC I maximum while closing with LUB38 || 90 mA 24 V AC I rms sealed with LUB32 || 90 mA 24 V AC I rms sealed with LUB38 |
Resistance To Electrostatic Discharge | 8 kV 3 in open air IEC 61000-4-2 || 8 kV 4 on contact IEC 61000-4-2 |
Safe Separation Of Circuit | 400 V SELV between the control and auxiliary circuits IEC 60947-1 || 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1 |
Width | 45 mm |
Tripping Threshold | 14.2 x Ir +/- 20 % |
Control Circuit Voltage Limits | 20 to 26.5 V AC 24 V in operation || 14.5 V AC 24 V drop-out |
Protective Treatment | TH IEC 60068 |
Product Or Component Type | advanced control unit |
Utilisation Category | AC-43 || AC-44 || AC-41 |
Fire Resistance | 960°C parts supporting live components IEC 60695-2-12 || 650°C IEC 60695-2-12 |
Load Type | 3-phase motor self-cooled |
Ambient Air Temperature For Storage | -40-85°C |
Immunity To Microbreaks | 3 ms |
Range | TeSys |
Non-Dissipating Shock Wave | 1 kV serial mode IEC 60947-6-2 || 2 kV common mode IEC 60947-6-2 |
Network Frequency | 40 to 60 Hz |
Device Application | motor control || motor protection |
Vibration Resistance | 2 gn 5-300 Hz power poles open IEC 60068-2-6 || 4 gn 5-300 Hz power poles closed IEC 60068-2-6 |
[Uimp] Rated Impulse Withstand Voltage | 6 kV IEC 60947-6-2 |
Shock Resistance | 10 gn power poles open IEC 60068-2-27 || 15 gn power poles closed IEC 60068-2-27 |
Motor Power Kw | 7.5 kW 400 to 440 V AC 50/60 Hz || 9 kW 500 V AC 50/60 Hz || 15 kW 690 V AC 50/60 Hz |
[Uc] Control Circuit Voltage | 24 V AC |
Phase Failure Sensitivity | yes |
Operating Altitude | 6561.68 ft (2000 m) |
Reset | manual reset |
Ip Degree Of Protection | IP20 front panel and wired terminals IEC 60947-1 || IP20 other faces IEC 60947-1 || IP40 front panel outside connection zone IEC 60947-1 |
Thermal Protection Adjustment Range | 4.5-18 A |
Thermal Overload Class | class 10 40-60 Hz -25-70°C IEC 60947-6-2 || class 10 40-60 Hz -25-70°C UL 508 |
Function Available | protection against overload and short-circuit || protection against phase failure and phase imbalance || manual reset || earth fault protection |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
Overload Module, 4.50 to 18A, 3P, 24VAC, Schneider Electric, Mfr#: LUCB18B
$149,99
Free shipping will be applied on orders over $50
Overload Module, Maximum Rated Motor Current Adjustment 18 A, Minumum Rated Motor Current Adjustment 4.5 A, Coil Voltage 24V AC, Compatible with Series TeSys Ultra, Terminal Connection Type Wire Leads, Trip Class 10, Phase Three, Maximum Voltage Rating 690V AC, Reset Type Manual, Standards ASEFA, ATEX Compliant, CCC, CE, CSA, CSA C22.2, EAC, EN 60947-6-2, Green Premium RoHS/REACH, IEC 60947-6-2, UL Listed, Compatible with Grainger Part Number 5AB64, 5AB67
9999 in stock
Must order in multiples of 1
Subtotal:
$149.99
You must be logged in to post a review.
Reviews
There are no reviews yet.