Overload Module, 0.35 to 1.40A, 3P, 24VAC, Schneider Electric, Mfr#: LUCC1XB

$149,99

Free shipping will be applied on orders over $50

Overload Module, Maximum Rated Motor Current Adjustment 1.4 A, Minumum Rated Motor Current Adjustment 0.35 A, Coil Voltage 24V AC, Compatible with Series TeSys Ultra, Terminal Connection Type Wire Leads, Trip Class 10, Phase Single, Maximum Voltage Rating 690V AC, Reset Type Manual, Standards ASEFA, ATEX Compliant, CCC, CE, CSA, CSA C22.2, EAC, EN 60947-6-2, Green Premium RoHS/REACH, IEC 60947-6-2, UL Listed, Compatible with Grainger Part Number 5AB63, 5AB64, 5AB65, 5AB67

9999 in stock

Must order in multiples of 1
Subtotal:
$149.99
Final shipping and tax calculated in checkout
Brand Name: Schneider Electric
Mfr #: LUCC1XB
Availability: Ships in 14 days
SKU: Category: ,

Analogues

PropertyValue
ItemOverload Module
Voltage24V AC
PhaseSingle
Thermal Setting Range (A)0.30 to 1.40
For Use WithLUxB32, LUxS12, LUxS32 Power Bases, Mfr. Series LUxB12
Trip Class10
Reset Type - RelayManual
Sensing MethodElectronic
FeaturesEarth Fault Protection
Current Range0.35 to 1.40A
Number of Poles3
StandardsASEFA, ATEX Compliant, CCC, CE, CSA, CSA C22.2, EAC, EN 60947-6-2, Green Premium RoHS/REACH, IEC 60947-6-2, UL Listed
Trip Class - Overload10
Reset TypeManual
Maximum Operating Temperature158 Degrees F
Coil Voltage24V AC
Minimum Operating Temperature-13 Degrees F
Terminal Connection TypeWire Leads
Maximum Rated Motor Current Adjustment1.4 A
Compatible with SeriesTeSys Ultra
Maximum Voltage Rating690V AC
Minumum Rated Motor Current Adjustment0.35 A
Compatible with Manufacturer Model NumberLU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380
Compatible Manufacturer Part NumberLU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380
Compatible Manufacturer Model NumberLU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380
For Use with Mfr. Model NumberLU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380
For Use With Mfr. Model NumberLU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380
Thermal Protection Adjustment Range0.35-1.4 A
Resistance To Electrostatic Discharge8 kV 3 in open air IEC 61000-4-2 || 8 kV 4 on contact IEC 61000-4-2
Tripping Threshold14.2 x Ir +/- 20 %
Ambient Air Temperature For Operation-25-70°C
Resistance To Radiated Fields10 V/m 3 IEC 61000-4-3
[Uc] Control Circuit Voltage24 V AC
Device Short NameLUCC
Main Function AvailableManual reset; Earth fault protection; Protection against phase failure and phase imbalance; Protection against overload and short-circuit
Resetmanual reset
Rated Motor Current Adjustment Range0.35 to 1.4 A
Control Circuit Voltage Limits20 to 26.5 V AC 24 V in operation || 14.5 V AC 24 V drop-out
Load Typesingle-phase motor
Width45 mm
Immunity To Microbreaks3 ms
Operating Time35 ms opening with LUB12 control circuit || 35 ms opening with LUB32 control circuit || 35 ms opening with LUB38 control circuit || 70 ms closing with LUB12 control circuit || 70 ms closing with LUB32 control circuit || 70 ms closing with LUB38 control circuit
Ip Degree Of ProtectionIP20 front panel and wired terminals IEC 60947-1 || IP20 other faces IEC 60947-1 || IP40 front panel outside connection zone IEC 60947-1
Immunity To Voltage Dips70 % / 500 ms IEC 61000-4-11
Network Frequency40 to 60 Hz
[Ui] Rated Insulation Voltage690 V IEC 60947-6-2 || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1
[Ue] Rated Operational Voltage690 V AC
Immunity To Radioelectric Fields10 V IEC 61000-4-6
Typical Current Consumption140 mA 24 V AC I maximum while closing with LUB12 || 220 mA 24 V AC I maximum while closing with LUB32 || 220 mA 24 V AC I maximum while closing with LUB38 || 70 mA 24 V AC I rms sealed with LUB12 || 90 mA 24 V AC I rms sealed with LUB32 || 90 mA 24 V AC I rms sealed with LUB38
Safe Separation Of Circuit400 V SELV between the control and auxiliary circuits IEC 60947-1 || 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
Function Availablemanual reset || earth fault protection || protection against phase failure and phase imbalance || protection against overload and short-circuit
Product Compatibilitypower base LUB12 || power base LUB32 || power base LUB38 || power base LUB120 || power base LUB320 || power base LUB380 || reversing contactor breaker LU2B12B || reversing contactor breaker LU2B32B
Height66 mm
Product CertificationsCE || UL || CSA || CCC || EAC || ASEFA || ATEX || Marine
Motor Power Kw0.09 kW 400 to 440 V AC 50/60 Hz 1 phase
Product Or Component Typeadvanced control unit
Rated Insulation Voltage690 V IEC 60947-6-2; 600 V UL 60947-4-1; 600 V CSA C22.2 No 60947-4-1
RangeTeSys
Non-Dissipating Shock Wave1 kV serial mode IEC 60947-6-2 || 2 kV common mode IEC 60947-6-2
Device Applicationmotor control || motor protection
Fixing Modeplug-in front face)
Operating Altitude6561.68 ft (2000 m)
Shock Resistance10 gn power poles open IEC 60068-2-27 || 15 gn power poles closed IEC 60068-2-27
Utilisation CategoryAC-41 || AC-44 || AC-43
Depth60 mm
Product NameTeSys Ultra
Product Specific Applicationbasic protection and advanced functions, communication
Ambient Air Temperature For Storage-40-85°C
Thermal Overload Classclass 10 40-60 Hz -25-55°C IEC 60947-6-2 || class 10 40-60 Hz -25-55°C UL 508
Fire Resistance960°C parts supporting live components IEC 60695-2-12 || 650°C IEC 60695-2-12
Compatibility CodeLUCC
Heat Dissipation2-2 W control circuit with LUB12 || 3-3 W control circuit with LUB32 || 3-3 W control circuit with LUB38
Resistance To Fast Transients2 kV 3 serial link IEC 61000-4-4 || 4 kV 4 all circuits except for serial link IEC 61000-4-4
Vibration Resistance2 gn 5-300 Hz power poles open IEC 60068-2-6 || 4 gn 5-300 Hz power poles closed IEC 60068-2-6
Protective TreatmentTH IEC 60068
[Uimp] Rated Impulse Withstand Voltage6 kV IEC 60947-6-2
Country of Origin (subject to change)France
Package Quantity1
TAGS:
#Overload Module
#0.35 to 1.40A
#24VAC
#Schneider Electric
#Mfr: LUCC1XB
#Schneider Electric
#mfr:LUCC1XB
#part number:LUCC1XB
#pn:LUCC1XB
#part code:LUCC1XB
#item number:LUCC1XB
#product code:LUCC1XB
#manufacturer number:LUCC1XB
#manufacturers part number:LUCC1XB
#mfn:LUCC1XB

Reviews

There are no reviews yet.

Add a review