Overload Module, 0.35 to 1.40A, 3P, 24VAC, Schneider Electric, Mfr#: LUCB1XB

$149,99

Free shipping will be applied on orders over $50

Overload Module, Maximum Rated Motor Current Adjustment 1.4 A, Minumum Rated Motor Current Adjustment 0.35 A, Coil Voltage 24V AC, Compatible with Series TeSys Ultra, Terminal Connection Type Wire Leads, Trip Class 10, Phase Three, Maximum Voltage Rating 690V AC, Reset Type Manual, Standards ASEFA, ATEX Compliant, CCC, CE, CSA, CSA C22.2, EAC, EN 60947-6-2, Green Premium RoHS/REACH, IEC 60947-6-2, UL Listed, Compatible with Grainger Part Number 5AB63, 5AB64, 5AB65, 5AB67

9999 in stock

Must order in multiples of 1
Subtotal:
$149.99
Final shipping and tax calculated in checkout
Brand Name: Schneider Electric
Mfr #: LUCB1XB
Availability: Ships in 14 days
SKU: Category: ,

Analogues

PropertyValue
ItemOverload Module
Voltage24V AC
PhaseThree
Thermal Setting Range (A)0.30 to 1.40
For Use WithLUxB32, LUxS12, LUxS32 Power Bases, Mfr. Series LUxB12
Trip Class10
Number of Poles3
FeaturesEarth Fault Protection
Trip Class - Overload10
StandardsASEFA, ATEX Compliant, CCC, CE, CSA, CSA C22.2, EAC, EN 60947-6-2, Green Premium RoHS/REACH, IEC 60947-6-2, UL Listed
Current Range0.35 to 1.40A
Sensing MethodElectronic
Reset Type - RelayManual
Maximum Voltage Rating690V AC
Minimum Operating Temperature-13 Degrees F
Maximum Rated Motor Current Adjustment1.4 A
Compatible with SeriesTeSys Ultra
Compatible with Manufacturer Model NumberLU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380
Minumum Rated Motor Current Adjustment0.35 A
Reset TypeManual
Maximum Operating Temperature158 Degrees F
Terminal Connection TypeWire Leads
Coil Voltage24V AC
Compatible Manufacturer Part NumberLU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380
Compatible Manufacturer Model NumberLU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380
For Use with Mfr. Model NumberLU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380
For Use With Mfr. Model NumberLU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380
Resistance To Fast Transients2 kV 3 serial link IEC 61000-4-4 || 4 kV 4 all circuits except for serial link IEC 61000-4-4
Product Compatibilitypower base LUB12 || power base LUB32 || power base LUB38 || power base LUB120 || power base LUB320 || power base LUB380 || reversing contactor breaker LU2B12B || reversing contactor breaker LU2B32B
Depth60 mm
[Ue] Rated Operational Voltage690 V AC
Non-Dissipating Shock Wave1 kV serial mode IEC 60947-6-2 || 2 kV common mode IEC 60947-6-2
Product Or Component Typeadvanced control unit
Load Type3-phase motor self-cooled
Typical Current Consumption140 mA 24 V AC I maximum while closing with LUB12 || 220 mA 24 V AC I maximum while closing with LUB32 || 220 mA 24 V AC I maximum while closing with LUB38 || 70 mA 24 V AC I rms sealed with LUB12 || 90 mA 24 V AC I rms sealed with LUB32 || 90 mA 24 V AC I rms sealed with LUB38
Heat Dissipation2-2 W control circuit with LUB12 || 3-3 W control circuit with LUB32 || 3-3 W control circuit with LUB38
Compatibility CodeLUCB
Motor Power Kw0.25 kW 400 to 440 V AC 50/60 Hz
Resistance To Radiated Fields10 V/m 3 IEC 61000-4-3
Product CertificationsCE || UL || CSA || CCC || EAC || ASEFA || ATEX || Marine
Resetmanual reset
Thermal Protection Adjustment Range0.35-1.4 A
[Uimp] Rated Impulse Withstand Voltage6 kV IEC 60947-6-2
Immunity To Microbreaks3 ms
Phase Failure Sensitivityyes
Thermal Overload Classclass 10 40-60 Hz -25-70°C IEC 60947-6-2 || class 10 40-60 Hz -25-70°C UL 508
Immunity To Voltage Dips70 % / 500 ms IEC 61000-4-11
Control Circuit Voltage Limits20 to 26.5 V AC 24 V in operation || 14.5 V AC 24 V drop-out
RangeTeSys
Product Specific Applicationbasic protection and advanced functions, communication
Ip Degree Of ProtectionIP20 front panel and wired terminals IEC 60947-1 || IP20 other faces IEC 60947-1 || IP40 front panel outside connection zone IEC 60947-1
Product NameTeSys Ultra
Protective TreatmentTH IEC 60068
Operating Time35 ms opening with LUB12 control circuit || 35 ms opening with LUB32 control circuit || 35 ms opening with LUB38 control circuit || 70 ms closing with LUB12 control circuit || 70 ms closing with LUB32 control circuit || 70 ms closing with LUB38 control circuit
Fire Resistance960°C parts supporting live components IEC 60695-2-12 || 650°C IEC 60695-2-12
[Ui] Rated Insulation Voltage690 V IEC 60947-6-2 || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1
Resistance To Electrostatic Discharge8 kV 3 in open air IEC 61000-4-2 || 8 kV 4 on contact IEC 61000-4-2
Vibration Resistance2 gn 5-300 Hz power poles open IEC 60068-2-6 || 4 gn 5-300 Hz power poles closed IEC 60068-2-6
Ambient Air Temperature For Operation-25-70°C
Shock Resistance10 gn power poles open IEC 60068-2-27 || 15 gn power poles closed IEC 60068-2-27
Height66 mm
Safe Separation Of Circuit400 V SELV between the control and auxiliary circuits IEC 60947-1 || 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
Device Applicationmotor control || motor protection
Fixing Modeplug-in front face)
Ambient Air Temperature For Storage-40-85°C
Function Availableprotection against overload and short-circuit || protection against phase failure and phase imbalance || earth fault protection || manual reset
Immunity To Radioelectric Fields10 V IEC 61000-4-6
[Uc] Control Circuit Voltage24 V AC
Device Short NameLUCB
Width45 mm
Tripping Threshold14.2 x Ir +/- 20 %
Utilisation CategoryAC-41 || AC-44 || AC-43
Operating Altitude6561.68 ft (2000 m)
Network Frequency40 to 60 Hz
Country of Origin (subject to change)France
Package Quantity1
TAGS:
#Overload Module
#0.35 to 1.40A
#24VAC
#Schneider Electric
#Mfr: LUCB1XB
#Schneider Electric
#mfr:LUCB1XB
#part number:LUCB1XB
#pn:LUCB1XB
#part code:LUCB1XB
#item number:LUCB1XB
#product code:LUCB1XB
#manufacturer number:LUCB1XB
#manufacturers part number:LUCB1XB
#mfn:LUCB1XB

Reviews

There are no reviews yet.

Add a review