Property | Value |
---|---|
Item | Overload Module |
Voltage | 110-240V AC/110-220V DC |
Phase | Single |
Thermal Setting Range (A) | 0.30 to 1.40 |
For Use With | LUxB32, LUxS12, LUxS32 Power Bases, Mfr. Series LUxB12 |
Current Range | 0.35 to 1.40A |
Trip Class - Overload | 10 |
Trip Class | 10 |
Standards | ASEFA, ATEX Compliant, CCC, CE, CSA, CSA C22.2, EAC, EN 60947-6-2, Green Premium RoHS/REACH, IEC 60947-6-2, UL Listed |
Features | Earth Fault Protection |
Number of Poles | 3 |
Sensing Method | Electronic |
Reset Type - Relay | Manual |
Reset Type | Manual |
Compatible with Series | TeSys Ultra |
Minimum Operating Temperature | -13 Degrees F |
Maximum Operating Temperature | 158 Degrees F |
Maximum Voltage Rating | 690V AC |
Maximum Rated Motor Current Adjustment | 1.4 A |
Minumum Rated Motor Current Adjustment | 0.35 A |
Terminal Connection Type | Wire Leads |
Coil Voltage | 110-240V AC/DC |
Compatible with Manufacturer Model Number | LU2B12FU, LU2B32FU, LU2B38FU, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380 |
Compatible Manufacturer Part Number | LU2B12FU, LU2B32FU, LU2B38FU, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380 |
Compatible Manufacturer Model Number | LU2B12FU, LU2B32FU, LU2B38FU, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380 |
For Use with Mfr. Model Number | LU2B12FU, LU2B32FU, LU2B38FU, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380 |
For Use With Mfr. Model Number | LU2B12FU, LU2B32FU, LU2B38FU, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380 |
Resistance To Electrostatic Discharge | 8 kV 3 in open air IEC 61000-4-2 || 8 kV 4 on contact IEC 61000-4-2 |
Product Certifications | CE || UL || CSA || CCC || EAC || ASEFA || ATEX || Marine |
Heat Dissipation | 2-2 W control circuit with LUB12 || 3-3 W control circuit with LUB32 || 3-3 W control circuit with LUB38 |
Load Type | single-phase motor |
Fire Resistance | 960°C parts supporting live components IEC 60695-2-12 || 650°C IEC 60695-2-12 |
Ip Degree Of Protection | IP20 front panel and wired terminals IEC 60947-1 || IP20 other faces IEC 60947-1 || IP40 front panel outside connection zone IEC 60947-1 |
Device Short Name | LUCC |
Ambient Air Temperature For Storage | -40-85°C |
Fixing Mode | plug-in front face) |
Motor Power Kw | 0.09 kW 400 to 440 V AC 50/60 Hz 1 phase |
Operating Altitude | 6561.68 ft (2000 m) |
Range | TeSys |
Tripping Threshold | 14.2 x Ir +/- 20 % |
Product Compatibility | power base LUB12 || power base LUB32 || power base LUB38 || power base LUB120 || power base LUB320 || power base LUB380 || reversing contactor breaker LU2B12FU || reversing contactor breaker LU2B32FU || reversing contactor breaker LU2B38FU |
Vibration Resistance | 2 gn 5-300 Hz power poles open IEC 60068-2-6 || 4 gn 5-300 Hz power poles closed IEC 60068-2-6 |
Safe Separation Of Circuit | 400 V SELV between the control and auxiliary circuits IEC 60947-1 || 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1 |
Thermal Overload Class | class 10 40-60 Hz -25-55°C IEC 60947-6-2 || class 10 40-60 Hz -25-55°C UL 508 |
Non-Dissipating Shock Wave | 1 kV serial mode IEC 60947-6-2 || 2 kV common mode IEC 60947-6-2 |
Ambient Air Temperature For Operation | -25-70°C |
Shock Resistance | 10 gn power poles open IEC 60068-2-27 || 15 gn power poles closed IEC 60068-2-27 |
Immunity To Voltage Dips | 70 % / 500 ms IEC 61000-4-11 |
Function Available | protection against phase failure and phase imbalance || earth fault protection || manual reset || protection against overload and short-circuit |
Product Specific Application | basic protection and advanced functions, communication |
Protective Treatment | TH IEC 60068 |
[Ue] Rated Operational Voltage | 690 V AC |
Height | 66 mm |
Reset | manual reset |
Typical Current Consumption | 280 mA 110 to 240 V AC I maximum while closing with LUB12 || 280 mA 110 to 240 V AC I maximum while closing with LUB32 || 280 mA 110 to 240 V AC I maximum while closing with LUB38 || 280 mA 110 to 220 V DC I maximum while closing with LUB12 || 280 mA 110 to 220 V DC I maximum while closing with LUB32 || 280 mA 110 to 220 V DC I maximum while closing with LUB38 || 35 mA 110 to 240 V AC I rms sealed with LUB12 || 25 mA 110 to 240 V AC I rms sealed with LUB32 || 25 mA 110 to 240 V AC I rms sealed with LUB38 || 35 mA 110 to 220 V DC I rms sealed with LUB12 || 25 mA 110 to 220 V DC I rms sealed with LUB32 || 25 mA 110 to 220 V DC I rms sealed with LUB38 |
[Uc] Control Circuit Voltage | 110 to 240 V AC || 110 to 220 V DC |
Control Circuit Voltage Limits | 88 to 264 V AC 110 to 240 V in operation || 88 to 242 V DC 110 to 220 V in operation || 55 V AC 110 to 240 V drop-out || 55 V DC 110 to 220 V drop-out |
Compatibility Code | LUCC |
Product Name | TeSys Ultra |
[Ui] Rated Insulation Voltage | 690 V IEC 60947-6-2 || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1 |
Operating Time | 35 ms opening with LUB12 control circuit || 35 ms opening with LUB32 control circuit || 35 ms opening with LUB38 control circuit || 50 ms closing with LUB12 control circuit || 50 ms closing with LUB32 control circuit || 50 ms closing with LUB38 control circuit |
Resistance To Fast Transients | 2 kV 3 serial link IEC 61000-4-4 || 4 kV 4 all circuits except for serial link IEC 61000-4-4 |
Network Frequency | 40 to 60 Hz |
Immunity To Radioelectric Fields | 10 V IEC 61000-4-6 |
Product Or Component Type | advanced control unit |
Resistance To Radiated Fields | 10 V/m 3 IEC 61000-4-3 |
[Uimp] Rated Impulse Withstand Voltage | 6 kV IEC 60947-6-2 |
Utilisation Category | AC-44 || AC-41 || AC-43 |
Width | 45 mm |
Depth | 60 mm |
Immunity To Microbreaks | 3 ms |
Thermal Protection Adjustment Range | 0.35-1.4 A |
Device Application | motor control || motor protection |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
Overload Modul, 0.35 to 1.40A, Class 10, 3P, Schneider Electric, Mfr#: LUCC1XFU
$149,99
Free shipping will be applied on orders over $50
Overload Module, Maximum Rated Motor Current Adjustment 1.4 A, Minumum Rated Motor Current Adjustment 0.35 A, Coil Voltage 110-240V AC/DC, Compatible with Series TeSys Ultra, Terminal Connection Type Wire Leads, Trip Class 10, Phase Single, Maximum Voltage Rating 690V AC, Reset Type Manual, Standards ASEFA, ATEX Compliant, CCC, CE, CSA, CSA C22.2, EAC, EN 60947-6-2, Green Premium RoHS/REACH, IEC 60947-6-2, UL Listed, Compatible with Grainger Part Number 5AB63, 5AB64, 5AB66, 5AB68
9999 in stock
Must order in multiples of 1
Subtotal:
$149.99
You must be logged in to post a review.
Reviews
There are no reviews yet.