Overload Modul, 0.15 to 0.60A, Class 10, 3P, Schneider Electric, Mfr#: LUCBX6FU

$149,99

Free shipping will be applied on orders over $50

Overload Module, Maximum Rated Motor Current Adjustment 0.6 A, Minumum Rated Motor Current Adjustment 0.15 A, Coil Voltage 110-240V AC/DC, Compatible with Series TeSys Ultra, Terminal Connection Type Wire Leads, Trip Class 10, Phase Three, Maximum Voltage Rating 690V AC, Reset Type Manual, Standards ASEFA, ATEX Compliant, CCC, CE, CSA, CSA C22.2, EAC, EN 60947-6-2, Green Premium RoHS/REACH, IEC 60947-6-2, UL Listed, Compatible with Grainger Part Number 5AB63, 5AB64, 5AB66, 5AB68

9999 in stock

Must order in multiples of 1
Subtotal:
$149.99
Final shipping and tax calculated in checkout
Brand Name: Schneider Electric
Mfr #: LUCBX6FU
Availability: Ships in 14 days
SKU: Category: ,

Analogues

PropertyValue
ItemOverload Module
Voltage110-240V AC/110-220V DC
PhaseThree
Thermal Setting Range (A)0.15 to 0.60
For Use WithLUxB32, LUxS12, LUxS32 Power Bases, Mfr. Series LUxB12
Reset Type - RelayManual
Sensing MethodElectronic
Current Range0.15 to 0.60A
Trip Class10
Number of Poles3
StandardsASEFA, ATEX Compliant, CCC, CE, CSA, CSA C22.2, EAC, EN 60947-6-2, Green Premium RoHS/REACH, IEC 60947-6-2, UL Listed
Trip Class - Overload10
FeaturesEarth Fault Protection
Coil Voltage110-240V AC/DC
Maximum Operating Temperature158 Degrees F
Reset TypeManual
Minumum Rated Motor Current Adjustment0.15 A
Maximum Rated Motor Current Adjustment0.6 A
Compatible with Manufacturer Model NumberLU2B12FU, LU2B32FU, LU2B38FU, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380
Terminal Connection TypeWire Leads
Minimum Operating Temperature-13 Degrees F
Maximum Voltage Rating690V AC
Compatible with SeriesTeSys Ultra
Compatible Manufacturer Part NumberLU2B12FU, LU2B32FU, LU2B38FU, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380
Compatible Manufacturer Model NumberLU2B12FU, LU2B32FU, LU2B38FU, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380
For Use with Mfr. Model NumberLU2B12FU, LU2B32FU, LU2B38FU, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380
For Use With Mfr. Model NumberLU2B12FU, LU2B32FU, LU2B38FU, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380
[Ue] Rated Operational Voltage690 V AC
Control Circuit Voltage Limits88 to 264 V AC 110 to 240 V in operation || 88 to 242 V DC 110 to 220 V in operation || 55 V AC 110 to 240 V drop-out || 55 V DC 110 to 220 V drop-out
Phase Failure Sensitivityyes
Immunity To Voltage Dips70 % / 500 ms IEC 61000-4-11
Network Frequency40 to 60 Hz
Motor Power Kw0.09 kW 400 to 440 V AC 50/60 Hz
Fire Resistance960°C parts supporting live components IEC 60695-2-12 || 650°C IEC 60695-2-12
Resistance To Electrostatic Discharge8 kV 3 in open air IEC 61000-4-2 || 8 kV 4 on contact IEC 61000-4-2
Thermal Overload Classclass 10 40-60 Hz -25-70°C IEC 60947-6-2 || class 10 40-60 Hz -25-70°C UL 508
Product Or Component Typeadvanced control unit
Vibration Resistance2 gn 5-300 Hz power poles open IEC 60068-2-6 || 4 gn 5-300 Hz power poles closed IEC 60068-2-6
Ambient Air Temperature For Storage-40-85°C
Device Short NameLUCB
Typical Current Consumption280 mA 110 to 240 V AC I maximum while closing with LUB12 || 280 mA 110 to 240 V AC I maximum while closing with LUB32 || 280 mA 110 to 240 V AC I maximum while closing with LUB38 || 280 mA 110 to 220 V DC I maximum while closing with LUB12 || 280 mA 110 to 220 V DC I maximum while closing with LUB32 || 280 mA 110 to 220 V DC I maximum while closing with LUB38 || 35 mA 110 to 240 V AC I rms sealed with LUB12 || 25 mA 110 to 240 V AC I rms sealed with LUB32 || 25 mA 110 to 240 V AC I rms sealed with LUB38 || 35 mA 110 to 220 V DC I rms sealed with LUB12 || 25 mA 110 to 220 V DC I rms sealed with LUB32 || 25 mA 110 to 220 V DC I rms sealed with LUB38
Function Availablemanual reset || protection against phase failure and phase imbalance || protection against overload and short-circuit || earth fault protection
Tripping Threshold14.2 x Ir +/- 20 %
Thermal Protection Adjustment Range0.15-0.6 A
[Uimp] Rated Impulse Withstand Voltage6 kV IEC 60947-6-2
Immunity To Radioelectric Fields10 V IEC 61000-4-6
Depth60 mm
Product NameTeSys Ultra
Immunity To Microbreaks3 ms
Operating Time35 ms opening with LUB12 control circuit || 35 ms opening with LUB32 control circuit || 35 ms opening with LUB38 control circuit || 50 ms closing with LUB12 control circuit || 50 ms closing with LUB32 control circuit || 50 ms closing with LUB38 control circuit
Product Compatibilitypower base LUB12 || power base LUB32 || power base LUB38 || power base LUB120 || power base LUB320 || power base LUB380 || reversing contactor breaker LU2B12FU || reversing contactor breaker LU2B32FU || reversing contactor breaker LU2B38FU
[Ui] Rated Insulation Voltage690 V IEC 60947-6-2 || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1
Width45 mm
Utilisation CategoryAC-44 || AC-43 || AC-41
Operating Altitude6561.68 ft (2000 m)
Height66 mm
Compatibility CodeLUCB
Ip Degree Of ProtectionIP20 front panel and wired terminals IEC 60947-1 || IP20 other faces IEC 60947-1 || IP40 front panel outside connection zone IEC 60947-1
[Uc] Control Circuit Voltage110 to 240 V AC || 110 to 220 V DC
Safe Separation Of Circuit400 V SELV between the control and auxiliary circuits IEC 60947-1 || 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
Resistance To Radiated Fields10 V/m 3 IEC 61000-4-3
Shock Resistance10 gn power poles open IEC 60068-2-27 || 15 gn power poles closed IEC 60068-2-27
Heat Dissipation2-2 W control circuit with LUB12 || 3-3 W control circuit with LUB32 || 3-3 W control circuit with LUB38
Product Specific Applicationbasic protection and advanced functions, communication
Protective TreatmentTH IEC 60068
Product CertificationsCE || UL || CSA || CCC || EAC || ASEFA || ATEX || Marine
Device Applicationmotor control || motor protection
Fixing Modeplug-in front face)
Resetmanual reset
Load Type3-phase motor self-cooled
Resistance To Fast Transients2 kV 3 serial link IEC 61000-4-4 || 4 kV 4 all circuits except for serial link IEC 61000-4-4
RangeTeSys
Ambient Air Temperature For Operation-25-70°C
Non-Dissipating Shock Wave1 kV serial mode IEC 60947-6-2 || 2 kV common mode IEC 60947-6-2
Country of Origin (subject to change)France
Package Quantity1
TAGS:
#Overload Modul
#0.15 to 0.60A
#Class 10
#Schneider Electric
#Mfr: LUCBX6FU
#Schneider Electric
#mfr:LUCBX6FU
#part number:LUCBX6FU
#pn:LUCBX6FU
#part code:LUCBX6FU
#item number:LUCBX6FU
#product code:LUCBX6FU
#manufacturer number:LUCBX6FU
#manufacturers part number:LUCBX6FU
#mfn:LUCBX6FU

Reviews

There are no reviews yet.

Add a review