Property | Value |
---|---|
Item | Logic Relay |
Input Voltage | 24V AC/DC |
Output Type | Relay |
Amps | 8 A |
Number of Outputs | 8 |
Clock | No |
Display | 7 Segment LED |
Number of Inputs | 12 |
Width | 4.91 in |
Depth | 2.34 in |
Height | 4.24 in |
Counters | 16 |
Timers | 16 |
Standards | EN/IEC 61000-4-4 level 3 || EN/IEC 61000-4-6 level 3 || EN/IEC 61000-4-3 || EN/IEC 61000-4-12 || EN/IEC 61000-4-5 || EN/IEC 61000-4-11 || EN/IEC 61000-4-2 level 3 || EN/IEC 60068-2-27 Ea || EN/IEC 60068-2-6 Fc |
Response Time | 10 ms from state 0 to state 1)relay output || 5 ms from state 1 to state 0)relay output |
Repeat Accuracy | +/- 2 % 55 °C analogue input circuit |
[Us] Rated Supply Voltage | 24 V DC |
Voltage State 1 Guaranteed | u003e= 15 V I1 to IA and IH to IR discrete input circuit || u003e= 15 V IB to IG used as discrete input circuit |
Product Certifications | C-tick || UL || GL || CSA || GOST |
Clock Drift | 12 min/year 0-55 °C || 6 s/month 25-25 °C |
Pollution Degree | 2 EN/IEC 61131-2 |
Switching Capacity In Ma | u003e= 10 mA 12 V relay output) |
Backup Time | 10 years 25 °C |
Checks | program memory on each power up |
Output Thermal Current | 8 A for all 8 outputs relay output |
Maximum Supply Current | 100 mA without extension) |
Power Dissipation In W | 6 W without extension |
Cycle Time | 6-90 ms |
Overvoltage Category | III EN/IEC 60664-1 |
Conversion Error | +/- 5 % 25 °C analogue input circuit || +/- 6.2 % 55 °C analogue input circuit |
Operating Altitude | 6561.68 ft (2000 m) |
Temperature Probe Type | NTC 10k 25 °C || NTC 1000k 25 °C || KTY81 210/220/221/222/250 || Pt 500 |
Discrete Input Type | resistive |
Contacts Type And Composition | NO relay output |
Input Compatibility | 3-wire proximity sensors PNP discrete input |
[Uimp] Rated Impulse Withstand Voltage | 4 kV EN/IEC 60947-1 and EN/IEC 60664-1 |
Analogue Input Range | 0 to 10 V || 0 to 24 V |
Current State 0 Guaranteed | u003c= 0.5 mA IB to IG used as discrete input circuit) || u003c= 0.75 mA I1 to IA and IH to IR discrete input circuit) |
Tightening Torque | 0.5 N.m |
Local Display | without |
Current State 1 Guaranteed | u003e= 1.2 mA IB to IG used as discrete input circuit) || u003e= 2.2 mA I1 to IA and IH to IR discrete input circuit) |
Discrete Input Number | 12 EN/IEC 61131-2 type 1 |
Immunity To Microbreaks | 1 ms |
Maximum Altitude Transport | 3048 m |
Disturbance Radiated/Conducted | class B EN 55022-11 group 1 |
Conversion Time | smart relay cycle time analogue input circuit |
Discrete Input Current | 4 mA |
Input Impedance | 12 kOhm IB to IG used as analogue input circuit || 12 kOhm IB to IG used as discrete input circuit || 7.4 kOhm I1 to IA and IH to IR discrete input circuit |
Ip Degree Of Protection | IP20 IEC 60529 terminal block) || IP40 IEC 60529 front panel) |
Ambient Air Temperature For Operation | -20-40 °C in non-ventilated enclosure IEC 60068-2-1 and IEC 60068-2-2 || -20-55 °C IEC 60068-2-1 and IEC 60068-2-2 |
Reverse Polarity Protection | with |
Ambient Air Temperature For Storage | -40-70 °C |
Operating Rate In Hz | 0.1 Hz at Ie)relay output || 10 Hz no load)relay output |
Operating Distance | 10 m between stations, with screened cable (sensor not isolated) analogue input circuit |
Lsb Value | 39 mV analogue input circuit |
Mechanical Durability | 10000000 cycles relay output |
Discrete Input Voltage | 24 V DC |
Relative Humidity | 95-95 % without condensation or dripping water |
Number Or Control Scheme Lines | 0-240 ladder || 0-500 FBD |
Voltage State 0 Guaranteed | u003c= 5 V I1 to IA and IH to IR discrete input circuit || u003c= 5 V IB to IG used as discrete input circuit |
Analogue Input Number | 6 |
Electrical Durability | AC-12 500000 cycles 230 V, 1.5 A relay output EN/IEC 60947-5-1 || AC-15 500000 cycles 230 V, 0.9 A relay output EN/IEC 60947-5-1 || DC-12 500000 cycles 24 V, 1.5 A relay output EN/IEC 60947-5-1 || DC-13 500000 cycles 24 V, 0.6 A relay output EN/IEC 60947-5-1 |
Counting Frequency | 1 kHz discrete input |
Product Or Component Type | compact smart relay |
Output Voltage Limits | 24 to 250 V AC relay output) || 5 to 30 V DC relay output) |
Analogue Input Resolution | 8 bits |
Connections - Terminals | screw terminals, 1 x 0.2 to 1 x 2.5 mm² AWG 25 to AWG 14) semi-solid || screw terminals, 1 x 0.2 to 1 x 2.5 mm² AWG 25 to AWG 14) solid || screw terminals, 1 x 0.25 to 1 x 2.5 mm² AWG 24 to AWG 14) flexible with cable end || screw terminals, 2 x 0.2 to 2 x 1.5 mm² AWG 24 to AWG 16) solid || screw terminals, 2 x 0.25 to 2 x 0.75 mm² AWG 24 to AWG 18) flexible with cable end |
Maximum Permissible Voltage | 30 V analogue input circuit |
Supply Voltage Limits | 19.2-30 V |
Analogue Input Type | common mode |
Environmental Characteristic | EMC directive EN/IEC 61000-6-2 || EMC directive EN/IEC 61000-6-3 || EMC directive EN/IEC 61000-6-4 || EMC directive EN/IEC 61131-2 zone B || low voltage directive EN/IEC 61131-2 |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
Logic Relay, 24VDC, Without Display, Schneider Electric, Mfr#: SR2E201BD
$314,99
Free shipping will be applied on orders over $50
Logic Relay, Input Voltage 24V AC/DC, Output Type Relay, 8 A Amps, Number of Inputs 12, Number of Outputs 8, Counters 16, Timers 16, No Clock, 7 Segment LED Display, Depth 2.34 in, Height 4.24 in, Width 4.91 in
9999 in stock
Must order in multiples of 1
Subtotal:
$314.99
You must be logged in to post a review.
Reviews
There are no reviews yet.