Logic Relay, 24VDC, Without Display, Schneider Electric, Mfr#: SR2E201BD

$314,99

Free shipping will be applied on orders over $50

Logic Relay, Input Voltage 24V AC/DC, Output Type Relay, 8 A Amps, Number of Inputs 12, Number of Outputs 8, Counters 16, Timers 16, No Clock, 7 Segment LED Display, Depth 2.34 in, Height 4.24 in, Width 4.91 in

9999 in stock

Must order in multiples of 1
Subtotal:
$314.99
Final shipping and tax calculated in checkout
Brand Name: Schneider Electric
Mfr #: SR2E201BD
Availability: Ships in 14 days
SKU: Category: ,

Analogues

PropertyValue
ItemLogic Relay
Input Voltage24V AC/DC
Output TypeRelay
Amps8 A
Number of Outputs8
ClockNo
Display7 Segment LED
Number of Inputs12
Width4.91 in
Depth2.34 in
Height4.24 in
Counters16
Timers16
StandardsEN/IEC 61000-4-4 level 3 || EN/IEC 61000-4-6 level 3 || EN/IEC 61000-4-3 || EN/IEC 61000-4-12 || EN/IEC 61000-4-5 || EN/IEC 61000-4-11 || EN/IEC 61000-4-2 level 3 || EN/IEC 60068-2-27 Ea || EN/IEC 60068-2-6 Fc
Response Time10 ms from state 0 to state 1)relay output || 5 ms from state 1 to state 0)relay output
Repeat Accuracy+/- 2 % 55 °C analogue input circuit
[Us] Rated Supply Voltage24 V DC
Voltage State 1 Guaranteedu003e= 15 V I1 to IA and IH to IR discrete input circuit || u003e= 15 V IB to IG used as discrete input circuit
Product CertificationsC-tick || UL || GL || CSA || GOST
Clock Drift12 min/year 0-55 °C || 6 s/month 25-25 °C
Pollution Degree2 EN/IEC 61131-2
Switching Capacity In Mau003e= 10 mA 12 V relay output)
Backup Time10 years 25 °C
Checksprogram memory on each power up
Output Thermal Current8 A for all 8 outputs relay output
Maximum Supply Current100 mA without extension)
Power Dissipation In W6 W without extension
Cycle Time6-90 ms
Overvoltage CategoryIII EN/IEC 60664-1
Conversion Error+/- 5 % 25 °C analogue input circuit || +/- 6.2 % 55 °C analogue input circuit
Operating Altitude6561.68 ft (2000 m)
Temperature Probe TypeNTC 10k 25 °C || NTC 1000k 25 °C || KTY81 210/220/221/222/250 || Pt 500
Discrete Input Typeresistive
Contacts Type And CompositionNO relay output
Input Compatibility3-wire proximity sensors PNP discrete input
[Uimp] Rated Impulse Withstand Voltage4 kV EN/IEC 60947-1 and EN/IEC 60664-1
Analogue Input Range0 to 10 V || 0 to 24 V
Current State 0 Guaranteedu003c= 0.5 mA IB to IG used as discrete input circuit) || u003c= 0.75 mA I1 to IA and IH to IR discrete input circuit)
Tightening Torque0.5 N.m
Local Displaywithout
Current State 1 Guaranteedu003e= 1.2 mA IB to IG used as discrete input circuit) || u003e= 2.2 mA I1 to IA and IH to IR discrete input circuit)
Discrete Input Number12 EN/IEC 61131-2 type 1
Immunity To Microbreaks1 ms
Maximum Altitude Transport3048 m
Disturbance Radiated/Conductedclass B EN 55022-11 group 1
Conversion Timesmart relay cycle time analogue input circuit
Discrete Input Current4 mA
Input Impedance12 kOhm IB to IG used as analogue input circuit || 12 kOhm IB to IG used as discrete input circuit || 7.4 kOhm I1 to IA and IH to IR discrete input circuit
Ip Degree Of ProtectionIP20 IEC 60529 terminal block) || IP40 IEC 60529 front panel)
Ambient Air Temperature For Operation-20-40 °C in non-ventilated enclosure IEC 60068-2-1 and IEC 60068-2-2 || -20-55 °C IEC 60068-2-1 and IEC 60068-2-2
Reverse Polarity Protectionwith
Ambient Air Temperature For Storage-40-70 °C
Operating Rate In Hz0.1 Hz at Ie)relay output || 10 Hz no load)relay output
Operating Distance10 m between stations, with screened cable (sensor not isolated) analogue input circuit
Lsb Value39 mV analogue input circuit
Mechanical Durability10000000 cycles relay output
Discrete Input Voltage24 V DC
Relative Humidity95-95 % without condensation or dripping water
Number Or Control Scheme Lines0-240 ladder || 0-500 FBD
Voltage State 0 Guaranteedu003c= 5 V I1 to IA and IH to IR discrete input circuit || u003c= 5 V IB to IG used as discrete input circuit
Analogue Input Number6
Electrical DurabilityAC-12 500000 cycles 230 V, 1.5 A relay output EN/IEC 60947-5-1 || AC-15 500000 cycles 230 V, 0.9 A relay output EN/IEC 60947-5-1 || DC-12 500000 cycles 24 V, 1.5 A relay output EN/IEC 60947-5-1 || DC-13 500000 cycles 24 V, 0.6 A relay output EN/IEC 60947-5-1
Counting Frequency1 kHz discrete input
Product Or Component Typecompact smart relay
Output Voltage Limits24 to 250 V AC relay output) || 5 to 30 V DC relay output)
Analogue Input Resolution8 bits
Connections - Terminalsscrew terminals, 1 x 0.2 to 1 x 2.5 mm² AWG 25 to AWG 14) semi-solid || screw terminals, 1 x 0.2 to 1 x 2.5 mm² AWG 25 to AWG 14) solid || screw terminals, 1 x 0.25 to 1 x 2.5 mm² AWG 24 to AWG 14) flexible with cable end || screw terminals, 2 x 0.2 to 2 x 1.5 mm² AWG 24 to AWG 16) solid || screw terminals, 2 x 0.25 to 2 x 0.75 mm² AWG 24 to AWG 18) flexible with cable end
Maximum Permissible Voltage30 V analogue input circuit
Supply Voltage Limits19.2-30 V
Analogue Input Typecommon mode
Environmental CharacteristicEMC directive EN/IEC 61000-6-2 || EMC directive EN/IEC 61000-6-3 || EMC directive EN/IEC 61000-6-4 || EMC directive EN/IEC 61131-2 zone B || low voltage directive EN/IEC 61131-2
Country of Origin (subject to change)France
Package Quantity1
TAGS:
#Logic Relay
#24VDC
#Without Display
#Schneider Electric
#Mfr: SR2E201BD
#Schneider Electric
#mfr:SR2E201BD
#part number:SR2E201BD
#pn:SR2E201BD
#part code:SR2E201BD
#item number:SR2E201BD
#product code:SR2E201BD
#manufacturer number:SR2E201BD
#manufacturers part number:SR2E201BD
#mfn:SR2E201BD

Reviews

There are no reviews yet.

Add a review