Logic Controller, 0.1A, 16 Outputs, 24VDC, Schneider Electric, Mfr#: TM221M32TK

$446,99

Free shipping will be applied on orders over $50

Logic Controller, Input Voltage 24V AC/DC, Output Type Relay, 0.1 A Amps, 2 Slots, Number of Inputs 16 Digital, 2 Analog, Number of Outputs 16, Counters 4, Timers Programmable, Yes Clock, 7 Segment LED Display, Port Type Modbus Serial (2xRJ45 - RS232/RS485), SD Card, USB Mini (Prog.), Memory 256 KB, Depth 3 in, Height 4.17 in, Width 2.75 in

9999 in stock

Must order in multiples of 1
Subtotal:
$446.99
Final shipping and tax calculated in checkout
Brand Name: Schneider Electric
Mfr #: TM221M32TK
Availability: Ships in 9 days
SKU: Category: ,

Analogues

PropertyValue
ItemLogic Controller
Input Voltage24V AC/DC
Output TypeRelay
Amps0.1 A
Number of Outputs16
ClockYes
Display7 Segment LED
Number of Inputs16 Digital, 2 Analog
Memory256 KB
Counters4
Port TypeModbus Serial (2xRJ45 - RS232/RS485), SD Card, USB Mini (Prog.)
Depth3 in
Width2.75 in
TimersProgrammable
Slots2
Height4.17 in
StandardsEN/IEC 60664-1 || EN/IEC 61010-2-201 || EN/IEC 61131-2
Response Time35 µs turn-off, I2 to I5 input || 5 µs turn-on, I0, I1, I6, I7 fast input || 35 µs turn-on, other terminals input || 5 µs turn-off, I0, I1, I6, I7 fast input || 100 µs turn-off, other terminals input || 5 µs turn-on, turn-off, Q0 to Q1 output || 50 µs turn-on, turn-off, Q2 to Q3 output || 300 µs turn-on, turn-off, other terminals output
Communication ServiceModbus master || Modbus slave
Mechanical Durability20000000 cycles transistor output
Surge Withstand2 kV power lines (AC) common mode EN/IEC 61000-4-5 || 2 kV relay output common mode EN/IEC 61000-4-5 || 1 kV I/O common mode EN/IEC 61000-4-5 || 1 kV shielded cable common mode EN/IEC 61000-4-5 || 0.5 kV power lines (DC) differential mode EN/IEC 61000-4-5 || 1 kV power lines (AC) differential mode EN/IEC 61000-4-5 || 1 kV relay output differential mode EN/IEC 61000-4-5 || 0.5 kV power lines (DC) common mode EN/IEC 61000-4-5
Discrete Output Logicpositive logic (source)
Realtime Clockwith
Memory capacity256 kB user application and data RAM 10000 instructions || 256 kB internal variables RAM
Analogue Input Resolution10 bits
Discrete Output Typetransistor
Exct Time For Event Task60 µs response time
Insulationbetween input and internal logic 500 V AC || between fast input and internal logic 500 V AC || non-insulated between inputs || between output and internal logic 500 V AC || non-insulated between analogue input and internal logic || non-insulated between analogue inputs
Resistance To Magnetic Fields30 A/m 50/60 Hz EN/IEC 61000-4-8
Communication Port ProtocolUSB port USB - SoMachine-Network || non isolated serial link Modbus master/slave - RTU/ASCII or SoMachine-Network
Local Signallingfor PWR 1 LED (green) || for RUN 1 LED (green) || for module error (ERR) 1 LED (red) || for SD card access (SD) 1 LED (green) || for BAT 1 LED (red) || for SL1 1 LED (green) || for SL2 1 LED (green) || for I/O state 1 LED per channel (green)
Product Or Component Typelogic controller
Transmission Rate1.2 to 115.2 kbit/s (115.2 kbit/s by default) 15-15 m RS485 || 1.2 to 115.2 kbit/s (115.2 kbit/s by default) 3-3 m RS232 || 480 Mbit/s USB
Absolute Accuracy Error+/- 1 % of full scale analog input
Data Backed Up256 kB built-in flash memory backup of application and data
Configurable Filtering Time0 ms input || 3 ms input || 12 ms input
Counter FunctionSingle phase; A/B; Pulse/direction
Conversion Time1 ms per channel + 1 controller cycle time analog input
Backup Time1 year 25 °C by interruption of power supply)
Discrete Input Current7 mA discrete input || 5 mA fast input
Supply Voltage Limits20.4-28.8 V
Execution Time For 1 K instruction0.3 ms event and periodic task; 0.7 ms other instruction
Resistance To Fast Transients2 kV EN/IEC 61000-4-4 power lines) || 2 kV EN/IEC 61000-4-4 relay output) || 1 kV EN/IEC 61000-4-4 I/O) || 1 kV EN/IEC 61000-4-4 Ethernet line) || 1 kV EN/IEC 61000-4-4 serial link)
Vibration Resistance3.5 mm 5-8.4 Hz symmetrical rail || 3.5 mm 5-8.4 Hz panel mounting || 1 gn 8.4-150 Hz symmetrical rail || 1 gn 8.4-150 Hz panel mounting
Pollution Degreeu003c= 2
Relative Humidity10-95 %, without condensation in operation) || 10-95 %, without condensation in storage)
Discrete Output Number16 transistor 2 fast output
Output Frequency100 kHz fast output (PWM/PLS mode) Q0 to Q1 || 5 kHz output Q2 to Q3 || 0.1 kHz output Q4 to Q15
Maximum Cable Distance Between Devicesshielded cable u003c10 m fast input || unshielded cable u003c30 m output || unshielded cable u003c30 m digital input || unshielded cable u003c1 m analog input || shielded cable u003c3 m fast output
Control Signal Typesingle phase || A/B || pulse/direction
Ambient Air Temperature For Operation-10-55 °C horizontal installation) || -10-35 °C vertical installation)
Discrete I/O Number32
Ip Degree Of ProtectionIP20 with protective cover in place
Voltage State 0 Guaranteedu003c= 5 V input
Discrete Input Number16 , discrete input 4 fast input IEC 61131-2 Type 1
Discrete Input Voltage24 V
Maximum Leakage Current0.1 mA transistor output
Mounting Supporttop hat type TH35-15 rail IEC 60715 || top hat type TH35-7.5 rail IEC 60715 || plate or panel with fixing kit
Ambient Air Temperature For Storage-25-70 °C
Maximum Size Of Object Areas8000 %MW memory words || 255 %TM timers || 512 %KW constant words || 512 %M memory bits || 255 %C counters
Clock Driftu003c= 30 s/month 25-25 °C
Resistance To Electrostatic Discharge8 kV in air EN/IEC 61000-4-2 || 4 kV on contact EN/IEC 61000-4-2
Immunity To Microbreaks10 ms
Maximum Tungsten Loadu003c2.4 W output and fast output
[Us] Rated Supply Voltage24 V DC
Discrete Output Voltage24 V DC
Analogue Input Number2 0 to 10 V
Positioning FunctionsPTO 2 pulse/direction 100 kHz) || PTO 1 CW/CCW 100 kHz)
MarkingCE
Supplyserial 1)serial link supply 5 V, u003c200 mA
Permitted Overload On Inputs+/- 30 V DC 5 min maximum)analog input || +/- 13 V DC permanent)analog input
Execution Time Per Instruction0.2 µs Boolean
Inrush Current35 A
Resistance To Electromagnetic Fields10 V/m 80 MHz to 1 GHz EN/IEC 61000-4-3 || 3 V/m 1.4 GHz to 2 GHz EN/IEC 61000-4-3 || 1 V/m 2 to 2.7 GHz EN/IEC 61000-4-3
Maximum Number Of I/O Expansion Module7 (local I/O-Architecture) || 14 (remote I/O-Architecture)
Battery TypeBR2032 lithium non-rechargeable 4 year(s)
Product CertificationsCSA || IACS E10 || cULus || LR || RCM || DNV-GL || EAC || ABS
Time For Event Task60 µs response time
Data Storage Equipment2 GB SD card optional)
Storage Altitude0-3000 m
Shock Resistance147 m/s² 11 ms
Discrete Output Current0.1 A
Maximum Power Consumption In W22.3 W 24 V with max number of I/O expansion module) || 3.5 W 24 V without I/O expansion module)
Protection Typeshort-circuit and overload protection with automatic reset || short-circuit protection on output || overload and short-circuit protection 0.2 A
Function AvailablePLS || PWM || frequency generator
Maximum Current Per Output Common1.6 A
Input Impedance3.4 kOhm discrete input || 100 kOhm analog input || 4.9 kOhm fast input
Electromagnetic Emissionconducted emissions 79 dBμV/m QP/66 dBμV/m AV power lines (AC))0.15-0.5 MHz EN/IEC 55011 || conducted emissions 73 dBμV/m QP/60 dBμV/m AV power lines (AC))0.5-300 MHz EN/IEC 55011 || conducted emissions 120 to 69 dBµV/m QP power lines)10-150 kHz EN/IEC 55011 || conducted emissions 63 dBμV/m QP power lines)1.5-30 MHz EN/IEC 55011 || radiated emissions 40 dBμV/m QP class A 10 m)30-230 MHz EN/IEC 55011 || conducted emissions 79 to 63 dBμV/m QP power lines)150-1500 kHz EN/IEC 55011 || radiated emissions 47 dBμV/m QP class A 10 m)200-1000 MHz EN/IEC 55011
Reset Time1 s automatic reset
Power Supply Output Current0.52-0.52 A 5 V expansion bus || 0.48-0.48 A 24 V expansion bus
Discrete Input Voltage TypeDC
Operating Altitude0 to 6561.68 ft (0 to 2000 m)
Integrated Connection TypeUSB port mini B USB 2.0 || non isolated serial link serial 1 RJ45 RS485 || non isolated serial link serial 2 RJ45 RS232/RS485
Lsb Value10 mV
Voltage State 1 Guaranteedu003e= 15 V input
Resistance To Conducted Disturbances10 V 0.15 to 80 MHz EN/IEC 61000-4-6 || 3 V 0.1 to 80 MHz Marine specification (LR, ABS, DNV, GL) || 10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) Marine specification (LR, ABS, DNV, GL)
Environmental Characteristicordinary and hazardous location
Regulation Loopadjustable PID regulator up to 14 simultaneous loops
Maximum Voltage Dropu003c1 V
Application Structure1 configurable freewheeling/cyclic master task || 1 cyclic auxiliary task || 8 interrupt tasks
Counting Input Number4 fast input (HSC mode) 100 kHz 32 bits
Electrical Connectionterminal block, 3 for connecting the 24 V DC power supply || connector, 4 for analogue inputs || mini B USB 2.0 connector for a programming terminal || HE-10 connector, 20 for inputs || HE-10 connector, 20 for outputs
Execution Time For 1 Kinstruction0.3 ms event and periodic task || 0.7 ms other instruction
Discrete Input Logicsink or source (positive/negative)
Country of Origin (subject to change)Taiwan, Province of China
Package Quantity1
TAGS:
#Logic Controller
#0.1A
#16 Outputs
#24VDC
#Schneider Electric
#Mfr: TM221M32TK
#Schneider Electric
#mfr:TM221M32TK
#part number:TM221M32TK
#pn:TM221M32TK
#part code:TM221M32TK
#item number:TM221M32TK
#product code:TM221M32TK
#manufacturer number:TM221M32TK
#manufacturers part number:TM221M32TK
#mfn:TM221M32TK

Reviews

There are no reviews yet.

Add a review