Property | Value |
---|---|
Item | Ground Fault Sensor |
Type | Toroid Sensor PA50 TYPE A 50mm (2 in) |
Amps AC | 85 |
Contains | 1.97 in Hole dia |
For Use With | TeSys T Motor Management System |
Length (In.) | 4.29 in |
Standards | RoHS Compliant |
Series | PA50 |
Rated Short-Time Withstand Current | 85 kA at 0.5 s |
Depth | 1.14 in |
Weight | 0.44 lb |
Rated Insulation Volts | 1000V |
Network Types | AC/DC |
Cable Dia. | 25 mm |
Heat Value | 1.42 MJ |
Connection Type | Screw Connection |
Operating Temp. Range | -35 to 70°C |
IP Rating | IP20; IP30 |
Inside Dia. | 50 mm |
Environment | Damp |
Application | Equipment Monitoring and Control |
Height | 4.25 in |
Hz | 45 to 440 Hz |
Storage Temp. Range | -55 to 85°C |
Impulse Withstand Voltage | 12 kV |
Features | Mercury Free; Overvoltage Category IV; Pollution Degree level 3 IEC 60664-1 |
Length | 88 mm |
Mounting | Fixed Plain Backplate, Fixed Profiled Sheet Metal, Fixed Slotted Backplate, Din Rail, Vigirex Relay |
Width | 3.46 in |
Compatible Series | RH10M, RH10P, RH197M, RH197P, RH21M, RH21P, RH68M, RH86M, RH86P, RH99M, RH99P, RHU, RHUs, RMH |
Product Type | Closed Toroid |
Number of Pieces | 1 |
Pollution Degree | Level 3 IEC 60664-1 |
Cable Outer Diameter | 0.98 in (25 mm) 0.08 in² (50 mm²) |
Environmental Characteristic | Exposure to damp heat not in service 25 to 55°C, RH 95%) 28 cycles IEC 60068-2-30; Salt mistKb/2 IEC 60068-2-52; Exposure to damp heat in servicecategory C2 48 hours IEC 60068-2-56 |
Transformer Ratio | 1/1000 |
Mounting Mode | Fixed plain backplate; Fixed profiled sheet metal; Fixed slotted backplate; Clip-on DIN rail; Clip-on Vigirex relay) |
Range Compatibility | VigiPacT RH10M residual current protection relay; VigiPacT RH10P residual current protection relay; VigiPacT RH21M residual current protection relay; VigiPacT RH21P residual current protection relay; VigiPacT RH68M residual current protection relay; VigiPacT RH86M residual current protection relay; VigiPacT RH86P residual current protection relay; VigiPacT RH99M residual current protection relay; VigiPacT RH99P residual current protection relay; VigiPacT RH197M residual current protection relay; VigiPacT RH197P residual current protection relay; VigiPacT RHU residual current protection relay; VigiPacT RHUs residual current protection relay; VigiPacT RMH residual current protection relay |
Current Sensor Type | A type closed toroid |
Connections - Terminals | Screw connection 0.00 in² (0.22 mm²) |
Product Certifications | CE |
Diameter | Inner 1.97 in (50 mm) |
Ambient Air Temperature For Storage | -67 to 185°F (-55 to 85°C) |
Overvoltage Category | IV |
Rated Operational Current | 85 A |
Product Or Component Type | Earth leakage current sensor |
Rated Insulation Voltage | 1000 V |
IP Degree Of Protection | Connectors IP20; IP30 |
Residual Short-Circuit Withstand Current | 85 kA / 0.5 s IEC 60947-2 |
Ambient Air Temperature For Operation | -31 to 158°F (-35 to 70°C) |
Rated Short Time Withstand Current | 85 kA 0.5 s |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
Ground Fault Sensor, Toroid, 50 mm, 85A, Schneider Electric, Mfr#: 50438
$417,99
Free shipping will be applied on orders over $50
Ground Fault Sensor, Application Equipment Monitoring and Control, Compatible Series RH10M, RH10P, RH197M, RH197P, RH21M, RH21P, RH68M, RH86M, RH86P, RH99M, RH99P, RHU, RHUs, RMH, Product Type Closed Toroid, Depth 1.14 in, Height 4.25 in, IP Rating IP20; IP30, Number of Pieces 1, Standards RoHS Compliant, Weight 0.44 lb, Width 3.46 in