Property | Value |
---|---|
Item | Ground Fault Sensor |
Type | Toroid Sensor GA300 TA 300mm (118 in) |
Amps AC | 630 |
Contains | 11.77 in Hole dia |
For Use With | TeSys T Motor Management System |
Standards | RoHS Compliant |
Length (In.) | 13.54 in |
Series | GA300 |
Length | 390 mm |
Rated Short-Time Withstand Current | 85 kA at 0.5 s |
Mounting | Fixed Cables |
Hz | 45 to 440 Hz |
Impulse Withstand Voltage | 12 kV |
Connection Type | Clip |
Cable Dia. | 150 mm |
Depth | 1.81 in |
Network Types | AC/DC |
Operating Temp. Range | -35 to 70°C |
Height | 14.17 in |
Inside Dia. | 291 mm |
Storage Temp. Range | -55 to 85°C |
Weight | 4.92 lb |
Features | Mercury Free; Overvoltage Category IV; Pollution Degree level 3 IEC 60664-1 |
Rated Insulation Volts | 1000V |
IP Rating | IP20; IP30 |
Application | Equipment Monitoring and Control |
Environment | Damp |
Width | 15.35 in |
Compatible Series | RH10M, RH10P, RH197M, RH197P, RH21M, RH21P, RH68M, RH86M, RH86P, RH99M, RH99P, RHU, RHUs, RMH |
Number of Pieces | 1 |
Product Type | Closed Toroid |
Product Certifications | CE |
Diameter | Inner 11.46 in (291 mm) |
Ambient Air Temperature For Storage | -67 to 185°F (-55 to 85°C) |
Cable Outer Diameter | 5.91 in (150 mm) 2 0.37 in² (240 mm²) |
Environmental Characteristic | Exposure to damp heat not in service 25 to 55°C, RH 95%) 28 cycles IEC 60068-2-30; Salt mistKb/2 IEC 60068-2-52; Exposure to damp heat in servicecategory C2 48 hours IEC 60068-2-56 |
Range Compatibility | VigiPacT RH10M residual current protection relay; VigiPacT RH10P residual current protection relay; VigiPacT RH21M residual current protection relay; VigiPacT RH21P residual current protection relay; VigiPacT RH68M residual current protection relay; VigiPacT RH86M residual current protection relay; VigiPacT RH86P residual current protection relay; VigiPacT RH99M residual current protection relay; VigiPacT RH99P residual current protection relay; VigiPacT RH197M residual current protection relay; VigiPacT RH197P residual current protection relay; VigiPacT RHU residual current protection relay; VigiPacT RHUs residual current protection relay; VigiPacT RMH residual current protection relay |
Rated Insulation Voltage | 1000 V |
Rated Operational Current | 630 A |
Mounting Mode | Fixed cables) |
Transformer Ratio | 1/1000 |
Ambient Air Temperature For Operation | -31 to 158°F (-35 to 70°C) |
Current Sensor Type | A type closed toroid |
Connections - Terminals | Connection by clip 0.01 in² (6.35 mm²) |
Residual Short-Circuit Withstand Current | 85 kA / 0.5 s IEC 60947-2 |
Rated Short Time Withstand Current | 85 kA 0.5 s |
Pollution Degree | Level 3 IEC 60664-1 |
Overvoltage Category | IV |
Product Or Component Type | Earth leakage current sensor |
IP Degree Of Protection | Connectors IP20; IP30 |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
Ground Fault Sensor, Toroid, 300 mm, 630A, Schneider Electric, Mfr#: 50442
$2014,99
Free shipping will be applied on orders over $50
Ground Fault Sensor, Application Equipment Monitoring and Control, Compatible Series RH10M, RH10P, RH197M, RH197P, RH21M, RH21P, RH68M, RH86M, RH86P, RH99M, RH99P, RHU, RHUs, RMH, Product Type Closed Toroid, Depth 1.81 in, Height 14.17 in, IP Rating IP20; IP30, Number of Pieces 1, Standards RoHS Compliant, Weight 4.92 lb, Width 15.35 in
9999 in stock
Must order in multiples of 1
Subtotal:
$2014.99
You must be logged in to post a review.
Reviews
There are no reviews yet.