Property | Value |
---|---|
Item | Electromechanical Timer |
Voltage | 120V AC |
Amps | 40 A |
Enclosure Type | Plastic |
Min. Time Setting | 1 hr |
Max. Time Setting | 23 hr |
Contact Form | DPST-NO |
Max. On/Off Cycles | 12 |
Depth | 3 13/16 in |
NEMA Rating | 3R |
Day Skipper | No |
Number of Poles | 2 |
Mount | Hole Wall |
Contact HP @ 240V | 5 hp |
Width | 5 1/2 in |
Description/Special Features | 3R Enclosures in Steel or Noncorrosive Plastic, Furnished with a Maximum of 12 Trippers, Has Adjustable Time Setting, Manual On/Off Override does not Alter Program, Snap-out Timing Mechanism, Up to 12 On/Off Settings Per Day |
Height | 9 7/16 in |
Type | 24-Hour |
Extra Trippers | 2E054 |
Finish | Metal Enclosure has Gray Enamel |
Contact HP @ 120V | 2 hp |
Nominal Max. Time Setting | 24 hr |
Number of Trippers Included | 2 |
Time Setting Range | 1 hr. to 23 hr. |
Operation Mode | 24 hour |
Operating Temperature Max | 130°C |
Resistive Load Ratings Ranges | 40 A, 120-240 VAC, 60 Hz |
UL Cerfication File Number | UL917 |
Power Consumption Max W | 3 W |
Pilot Duty Load Ratings | 1000 VA, 120-240 VAC, 60 Hz |
Inductive Load Ratings | 40 A, 240 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 120 VAC, 60 Hz |
Electronic Ballast Load Ratings | 16 A, 120 VAC; 16 A, 208 VAC; 16 A, 240 VAC; 16 A, 277 VAC |
Knockout Dimensions Back | (1) combination 1/2 |
Input Voltage Ranges | 120 VAC, 60 Hz |
Wiring Option | Terminals |
Product Width | 6 1/2 in; 165.1 mm |
Pilot Duty Load Ratings Ranges | 1000 VA, 120-240 VAC, 60 Hz |
Tungsten Load Ratings | 40 A, 120 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz |
Market | Commercial; Industrial |
Wire Size Max | #8 AWG |
Electronic Ballast Load Ratings Ranges | 16 A, 120-277 VAC |
Wire Size Min | #14 AWG |
Has Manual Override CVL | Yes |
Knockout Dimensions Bottom | (2) combination 1/2 |
Skipper Wheel Operation Mode | Not Included |
Number Of Circuits | 1 |
UL Certification | cULus |
CSA Certification | cCSAus |
Applications | Timing/Scheduling ON/OFF; Indoor Lighting Control; Outdoor Lighting Control |
Operating Temperature Min | -40°C |
Resistive Load Ratings | 40 A, 240 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 120 VAC, 60 Hz |
Inductive Load Ratings Ranges | 40 A, 120-240 VAC, 60 Hz |
Switch Type | DPST |
Minimum On Off Time | 1 hour |
Timing Interval | 1 hr |
Packaging Applications | Indoor/Outdoor Lighting; Signs; Filters; Electric Fences; Fans; Conveyors; Pool Heaters; Blowers; Pumps |
Tungsten Load Ratings Ranges | 40 A, 120-240 VAC, 60 Hz |
Solutions | Machinery u0026 Pumps; Panel Integrators |
Product Height | 10 in; 254 mm |
Application Compatibilities | LED; HID |
Product Depth | 4 in; 101.6 mm |
Motor Load Ratings | 2 HP, 24 FLA @ 120 VAC, 60 Hz; 5 HP, 28 FLA @ 240 VAC, 60 Hz |
Maximum On Off Operations | 12 |
Maximum ON/OFF Operations | 12 |
Tungsten Range(s) | 40 A, 120-240 VAC, 60 Hz |
Minimum ON/OFF Times | 1 hour |
Input Voltage Range(s) | 120 VAC, 60 Hz |
Maximum Power Consumption (W) | 3 W |
Inductive | 40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz |
Tungsten (NO) | 40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz |
Electronic Ballast | 16 A, 120 VAC, 16 A, 208 VAC, 16 A, 240 VAC, 16 A, 277 VAC |
Skipper Wheel | Not Included |
Motor Load Ratings Ranges | 2 HP, 24 FLA @ 120 VAC, 60 Hz; 5 HP, 28 FLA @ 240 VAC, 60 Hz |
Has Manual Override | Yes |
Product Height (in) | 10 |
Operating Temperature Max (°F) | 130 |
Pilot Duty (NO) | 1000 VA, 120-240 VAC, 60 Hz |
Features | Direct 24-hour control of most loads; Up to 12 ON/OFF operations each day with minimum ON/OFF times of one hour; Manual override; One ON and one OFF tripper included |
Resistive | 40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz |
Operating Temperature Min (°F) | -40 |
Product Width (in) | 6.5 |
Product Depth (in) | 4 |
Country of Origin (subject to change) | Mexico |
Package Quantity | 1 |
Electromechanical Timer, 24 Hour, Dpst, Intermatic, Mfr#: T103P
$128,10
Free shipping will be applied on orders over $50
Electromechanical Timer, 24-Hour, Number of Poles 2, Contact Form DPST-NO, Voltage 120V AC, Amps 40 A, Contact HP @ 120V 2 hp, Contact HP @ 240V 5 hp, Day Skipper No, Enclosure Type Plastic, Finish Metal Enclosure has Gray Enamel, NEMA Rating 3R, Min. Time Setting 1 hr, Max. Time Setting 23 hr, Max. On/Off Cycles 12, Width 5 1/2 in, Depth 3 13/16 in, Height 9 7/16 in, Number of Trippers Included 2, Extra Trippers 2E054
9999 in stock
Must order in multiples of 1
Subtotal:
$128.1
You must be logged in to post a review.
Reviews
There are no reviews yet.